Desa (V)T32EN SERIES Indoor Fireplace User Manual


 
www.desatech.com
111987-01D20
11. Peel off backing paper and stick supplied
wiring diagram decal on rebox bottom ap-
proximately 12" in front of blower (see Figure
28, page 19).

    
   

    -


FIREPLACE
INSTALLATION
Continued
Figure 30 - Blower Wiring Diagram for
Thermostat-Controlled Models
Blue
Variable
Fan Switch
Fan Switch
(N.O.)
Green
White
On
110/115
V.A.C.
Blower
Motor
Black
Off
1
2
Black
INSTALLING GAS PIPING TO
FIREPLACE LOCATION
  
   


   
   


   


WARNING: For natural
    

 

Installation Items Needed
Before installing replace, make sure you have the
items listed below.
external regulator (supplied by installer)
piping (check local codes)
sealant (resistant to propane/LP gas)
equipment shutoff valve *
test gauge connection *
sediment trap
tee joint
pipe wrench
approved exible gas line with gas connector
(if allowed by local codes)
* A CSA design-certied equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to test
gauge connection. Purchase the CSA design-certi-
ed equipment shutoff valve from your retailer.
For propane/LP connection only, the installer must
supply an external regulator. The external regula-
tor will reduce incoming gas pressure. You must
reduce incoming gas pressure to between 11 and 14
inches of water. If you do not reduce incoming gas
pressure, replace regulator damage could occur.
Install external regulator with the vent pointing
down as shown in Figure 31. Pointing the vent
down protects it from freezing rain or sleet.
CAUTION: Use only new,
     -


     

-


Figure 31 - External Regulator with Vent
Pointing Down (Propane/LP Only)
Propane/LP
Supply Tank
External
Regulator
Vent
Pointing
Down