Roof Opening Chart
WARNING: Do not operate an unvented gas log
set in this fireplace with the chimney removed.
Chimney Maintenance
Have your chimney system cleaned and inspected regularly to
ensure safe and efficient operation.
Using
Figure 24 and the roof opening chart below, determine the
opening that will be required for the pitch of your particular
roof.
Figure 25 - Roof Opening
FINISHING YOUR CHIMNEY SYSTEM
Maximum Chimney Height (Cont.)
Chimney
Maintenance
VENTING INSTALLTION
Continued
Figure 24 - Maximum Chimney Height
Before cutting hole, temporarily remove shingles around area to be
opened.
After preparing the opening on the roof, continue to add
sections
of pipe until it extends a minimum of 30 inches above
highest point of roof cutout (see Figure 25).
With
the termination, the minimum height should add up to 3 feet
(see
10-Foot Rule and Figure 22, page 10).
Opening
A
19" Min.
(48.26cm)
30" Min.
(76.2cm)
2" Min.
(5.08cm)
2" Min.
(5.08cm)
2" Min.
(5.08cm)
30° Offset/
Return
30°
Firestop
Spacer
Firestop
Spacer
MAXIMUM
HEIGHT
CHASE
TERMIN
ATION
40 F
T
.
(12m)
PITCH Opening “A” Use Flashing
(degrees) Max. (inches) Model Number
FLAT 19
0-6/12 23
1
/4
V6F-10DM
(26.6 deg. Slope)
6/12-12/12 30
3
/4 V12F-10DM
(56.3 deg. Slope)
V6F-10DM
Firestop
Spacer
Flashing
Storm
Collar
MINIMUM
HEIGHT
15 F
T.
(4.5m)
RTL-12D RTL-12D
STL-12D