Desa VP10TA Electric Heater User Manual


 
14
104083
PROPANE/LP GAS HEATER
®
TROUBLESHOOTING
Continued
OBSERVED PROBLEM
Burner plaques do not light after ODS/pilot is lit
Delayed ignition of burner plaques
Burner backfiring during combustion
Burner plaques do not glow
Slight smoke or odor during initial operation
Heater produces a clicking/ticking noise
just after burner is lit or shut off
White powder residue forming within burner
box or on adjacent walls or furniture
REMEDY
1. Clean burner orifice(s) (see Cleaning
and Maintenance, page 12) or replace
burner orifice(s)
2. Replace burner orifice(s)
3. Contact local propane/LP gas company
1. Contact local propane/LP gas company
2. Clean burner orifice(s) (see Cleaning
and Maintenance, page 12) or replace
burner orifice(s)
1. Clean burner orifice(s) (see Cleaning
and Maintenance, page 12) or replace
burner orifice(s)
2. Contact local propane/LP gas company
3. Replace burner
4. Replace gas regulator
1. Replace burner
2. Contact local propane/LP gas company
3. Turn control knob to higher setting
1. Problem will stop after a few hours of
operation
1. This is common with most heaters. If
noise is excessive, contact qualified
service person
1. Turn heater off when using furniture
polish, wax, carpet cleaners, or similar
products
POSSIBLE CAUSE
1. Burner orifice(s) is clogged
2. Burner orifice(s) diameter is too small
3. Inlet gas pressure is too low
1. Manifold pressure is too low
2. Burner orifice(s) is clogged
1. Burner orifice(s) is clogged or damaged
2. Inlet gas pressure is too low
3. Burner damaged
4. Gas regulator defective
1. Plaque damaged
2. Inlet gas pressure is too low
3. Control knob set too low
1. Residues from manufacturing processes
1. Metal expanding while heating or
contracting while cooling
1. When heated, vapors from furniture
polish, wax, carpet cleaners, etc. turn
into white powder residue
www.desatech.com