Desa VN10 Gas Heater User Manual


 
11
101851
OWNER’S MANUAL
BURNER FLAME PATTERN
Figure 20 shows a correct burner flame
pattern. Figure 21 shows an incorrect burner
flame pattern.
Figure 20 - Correct Burner Flame Pattern
(Model VN10 Shown)
Figure 21 - Incorrect Burner Flame Pattern
(Model VN10 Shown)
If burner flame pattern is incorrect, as shown
in Figure 21
turn heater off (see To Turn Off Gas
to Appliance, page 10)
see Troubleshooting, pages 12
through 14
CLEANING AND
MAINTENANCE
ODS/PILOT AND BURNER
ORIFICE
Use a vacuum cleaner, pressurized
air, or small, soft bristled brush to
clean.
CABINET
Air Passageways
Use a vacuum cleaner or pressurized
air to clean.
Exterior
Use a soft cloth dampened with a
mild soap and water mixture. Wipe
the cabinet to remove dust.
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, etc.
GRH/OV 009GOOD PILOT
GRH/OV 010BAD PILOT
If pilot flame pattern is incorrect, as shown
in Figure 19
turn heater off (see To Turn Off Gas
to Appliance, page 10)
see Troubleshooting, pages 12
through 14
Pilot Burner
Thermocouple
Thermocouple
Pilot Burner
Check pilot flame pattern and burner flame
pattern often.
PILOT FLAME PATTERN
Figure 18 shows a correct pilot flame pat-
tern. Figure 19 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the heater will shut
down.
INSPECTING
BURNER
Figure 19 - Incorrect Pilot Flame Pattern
Figure 18 - Correct Pilot Flame Pattern
MANUAL LIGHTING
PROCEDURE
1. Remove front panel (see Figure 10,
page 7).
2. Follow steps 1 through 5 under Light-
ing Instructions, page 10.
3. With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.
4. Keep control knob pressed in for 10
seconds after pilot is lit. After 10 sec-
onds, release control knob.
5. Replace front panel.
OPERATING
HEATER
Continued