www.desatech.com
116240-01E 33
TROUBLESHOOTING
Continued
-
1. Gas leak.
2. Control valve defective
1. Foreign matter between
control valve and burner
2. Gas leak.
1. Debris around burner air
mixer
2. Improper vent conguration
1. Air holes at burner inlet
blocked
2. Burner ame holes blocked
3. Improper venting or exces-
sive blockage
4. Excessive amounts of em-
bers and pan material
Gas odor even when control
knob is in OFF position
Gas odor during combustion
Glass soots
Dark residue on logs or inside
of replace
REMEDY
1. Locate and correct all leaks (see
Checking Gas Connections, page
23)
2. Replace control valve
1. Take apart gas tubing and remove
foreign matter
2. Locate and correct all leaks (see
Checking Gas Connections,
page 23)
1. Inspect the opening at the base of
the burner to see that it is NOT
packed with any type of material
2. Check vent configuration speci-
cation (see Venting Installation
Instructions, page 9)
1. Clean out air holes at burner inlets.
Periodically repeat as needed
2. Remove blockage
3. Have the vent system inspected,
including the termination cap.
Remove any restrictions or ob-
struction
4. Clear excess embers until a mini-
mum gap of 1/2" remains under the
grate