www.desatech.com
116010-01C 13
IMPORTANT: The glass must be allowed to
warm slowly and evenly. The tempered glass will
withstand a gradual temperature rise to 550° F,
which is more than a normal re will generate.
Such materials as pitch/wax laden logs, very dry
mill end lumber and large amounts of paper or
cardboard boxes can create an excessively hot re
and should not be burned in this replace. Always
keep the re well back from the doors and never
allow ames to contact the glass.
equipped with glass doors
should be operated only with
doors fully opened or doors fully
Cleaning Glass
Clean glass with any commercial glass cleaner or
soap and water. Do not use any abrasive material
to clean glass. Do not clean glass with any cool
water if glass is still hot from the re and smoke.
A gas line or gas log lighter may be installed for the
purpose of installing a vented or vent-free deco-
rative gas appliance incorporating an automatic
shutoff device and complying with the Standard
for Decorative Gas Appliances for Installation in
Vented Fireplaces, ANSI Z21.60 or American Gas
Association draft requirements for Gas Fired Log
Lighters for Wood Burning Fireplaces, Draft NO.
4 dated August, 1993.
If you wish to install an unvented (vent-free) gas
log set, only unvented gas log sets which have been
found to comply with the standard for unvented
room heaters, ANSI Z21.11.2 are to be installed
in this replace.
The damper handle, which opens and closes the
damper blade, is located in the upper front face
of the replace. Pushing the handle forward and
up through the keyway slot will free damper
blade to automatically open. Pushing the handle
forward and down will lock damper blade closed
(see Figure 25).
OPERATION AND
MAINTENANCE GUIDELINES
Continued
Figure 25 - Operating Damper Handle
Damper
Weight
To Close
Damper
To Open
Damper
Damper
Weight
The outside air kit lever is located at the left and
right hand sides of replace (see Figure 26). Lift-
ing lever up will free the outside air door to open.
Pulling lever down will lock the door.
-
has been designed to keep the
Open Position
Closed Position
Figure 26 - Outside Air Kit Lever