111826-01F
For more information, visit www.desatech.com
15
15
OPERATING HEATER (REMOTE-READY MODELS)
Lighting Instructions (Cont.)
To Turn Off Gas To Appliance
Manual Lighting Procedure
Remote Control Operation
OPERATING HEATER
Continued
Figure 18 - Control Knob and Ignitor Button Location,
Remote Ready Controlled
Remote Control
7. With control knob pressed in, press and release ignitor but-
ton. This will light pilot. The pilot is attached to the front
burner. If needed, keep press ing ig ni tor button until pilot
lights.
Note: If pilot does not stay lit, con tact a qualifi ed service
person or gas sup pli er for repairs. Until repairs are made,
light pilot with match. To light pilot with match, see Man u al
Light ing Procedure, column 2.
8. Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
• If control knob does not pop out when released, contact
a qualifi ed ser vice person or gas supplier for re pairs.
Note: If pilot goes out, repeat steps 4 through 8, pages
14 & 15.
9. Slightly push in and turn control knob counterclockwise
to the ON position.
10. Wait one minute and switch selector switch to the ON po-
si tion to light burners. Note: AUTO is only func tion al when
using GWMT1 or GWMS2 optional accessories.
11. Set fl ame adjustment knob to any lev el be tween HI and
LO.
CAUTION: Do not try to ad just heating levels by
using the equipment shutoff valve.
WARNING: Make sure the selector switch is in the
OFF po si tion when you are away from home for long
periods of time. Heater will come on au to mat i cal ly
with selector switch in the ON position.
Shutting Off Heater
1. Turn control knob clockwise to the OFF po-
si tion.
2a. Set selector switch in the OFF po si tion.
2b. If Using Optional Hand-Held Re mote: Set selector switch
in the OFF po si tion to pre vent drain ing battery.
Shutting Off Burner Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing
one of the fol low ing:
1. Turn control knob clockwise to the PILOT po-
si tion.
2. Use remote control manual OFF button.
3. Set selector switch in the OFF po si tion.
Figure 19 - Pilot (Propane/LP)
Ignitor
Electrode
Pilot
Burner
Pilot (Natural)
Ignitor
Electrode
Pilot
Burner
TO TURN OFF GAS TO APPLIANCE
MANUAL LIGHTING PROCEDURE
1. Fol low steps 1 through 6 under Light ing In struc tions, page
14.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob. Now follow
steps 9 through 11, Lighting In struc tions, column 1.
O
F
F
P
I
L
O
T
O
N
L
O
I
H
AUTO
OFF
ON
Control Knob
Ignitor Button
Flame Adjustment Knob
Selector Switch in
OFF Position
REMOTE OFF ON
Remote Control Operation
GHRCB Series Operation:
1. After lighting, let pilot fl ame burn for about one minute.
Turn control knob to ON position. Adjust fl ame ad just ment
knob anywhere between HI and LO. Slide the se lec tor
switch to the RE MOTE po si tion. Note: The burn ers may
light if hand-held re mote ON button was on when se lec tor
switch was last turned off. You can now turn the burn ers
on and off with the hand-held re mote con trol unit.
REMOTE CONTROL OPERATION