Desa VF-18P-PJD Water Heater User Manual


 
www.desatech.com
111826-04B 9
INSTALLATION AND CLEARANCES
FOR VENT-FREE OPERATION
WARNING: Maintain the
minimum clearances. If you can,
provide greater clearances from
floor, ceiling and adjoining wall.
INSTALLATION
Continued
Carefully follow the instructions below. This will
ensure safe installation into a masonry, UL127-
listed manufactured fireplace or listed vent-free
firebox enclosure.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and wall
should follow diagram in Figure 4.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/
2
" from the wall. This combus-
tible material must be 4" from the side of the
fireplace cabinet (see Figure 4).
Note: When installing your gas logs into
a manufactured firebox, follow firebox
manufacturerʼs instructions for minimum
clearances to combustible materials.
B.
Clearances from the top of the fireplace opening
to the ceiling should not be less than 42 inches.
Figure 4 - Minimum Clearance for
Combustible to Wall
*Minimum 16 inches from Side Wall
*
Example
LOG SIZING REQUIREMENTS
Minimum Firebox Size
Log Front Rear*
Size Height Depth Width Width
18" 17" 14" 24" 20"
24" 17" 14" 28" 22"
30" 24" 17
1
/
2
" 42" 28
3
/
4
"
MINIMUM FIREPLACE
CLEARANCE TO
COMBUSTIBLE MATERIALS
Log Size 18", 24", 30"
Side Wall 16"
Ceiling 42"
Floor 5"
*Measured at 14" depth
Minimum Noncombustible Material
Clearances
If Not Using Mantel
Note: If using a mantel, proceed to If Using
Mantel. If not using a mantel, follow the informa-
tion below.
You must have noncombustible material(s) above
fireplace opening. Noncombustible materials
(such as slate, marble, tile, etc.) must be at least
1/2 inch thick. With sheet metal, you must have
noncombustible material behind it. Noncombus
-
tible material must extend at least 8" up (for all
models). If noncombustible material is less than
12", you must install the fireplace hood accessory
24" and 30" models only). See Figure 5, page 10,
for minimum clearances.
If Using Mantel
You must have noncombustible material(s) above
the fireplace opening. Noncombustible materials
(such as slate, marble, tile, etc.) must be at least
1/2 inch thick. With sheet metal, you must have
noncombustible material behind it. Noncombus
-
tible material must extend at least 8 inches up (for
all models). If noncombustible material is less than
12", you must install the fireplace hood accessory.
Even if noncombustible material is more than 12",
you may need the hood accessory to deflect heat
away from your mantel shelf. See Figures 5, 6 and
7, page 10, for minimum clearances.