Desa VF-24N-EMU Electric Heater User Manual


 
111826-05
For more information, visit www.desatech.com
15
15
OPERATING HEATER (REMOTE-READY MODELS)
Lighting Instructions (Cont.)
To Turn Off Gas To Appliance
Manual Lighting Procedure
Remote Control Operation
OPERATING HEATER
Continued
Figure 18 - Control Knob and Ignitor Button Location,
Remote Controlled
Remote Control
7. With control knob pressed in, press and release ignitor but-
ton. This will light pilot. The pilot is attached to the front
burner. If needed, keep pressing ignitor button until pilot
lights.
Note: If pilot does not stay lit, contact a qualified service
person or gas supplier for repairs. Until repairs are made,
light pilot with match. To light pilot with match, see Manual
Lighting Procedure, column 2.
8. Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
If control knob does not pop out when released, contact
a qualified service person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4 through 8, pages
14 & 15.
9. Slightly push in and turn control knob counterclockwise
to the ON position.
10. Wait one minute and switch selector switch to the ON po-
sition to light burners. Note: AUTO is only functional when
using GWMT1 or GWMS2 optional accessories.
11. Set flame adjustment knob to any level between HI and
LO.
CAUTION: Do not try to adjust heating levels by
using the equipment shutoff valve.
WARNING: Make sure the selector switch is in the
OFF position when you are away from home for long
periods of time. Heater will come on automatically
with selector switch in the ON position.
Shutting Off Heater
1. Turn control knob clockwise to the OFF po-
sition.
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Remote: Set selector switch
in the OFF position to prevent draining battery.
Shutting Off Burner Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing
one of the following:
1. Turn control knob clockwise to the PILOT po-
sition.
2. Use remote control manual OFF button.
3. Set selector switch in the OFF position.
Figure 19 - Pilot (Propane/LP)
Ignitor
Electrode
Pilot
Burner
Pilot (Natural)
Ignitor
Electrode
Pilot
Burner
TO TURN OFF GAS TO APPLIANCE
MANUAL LIGHTING PROCEDURE
1. Follow steps 1 through 6 under
Lighting Instructions
, page
14.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob. Now follow
steps 9 through 11,
Lighting Instructions
, column 1.
O
F
F
L
O
I
H
AUTO
OFF
ON
Control Knob
Ignitor Button
Flame Adjustment Knob
Selector Switch in
OFF Position
REMOTE OFF ON
Remote O
nOf
f
Fireplac
e
Remot
e
Remote Control Operation
1. After lighting, let pilot flame burn for about one minute.
Turn control knob to ON position. Adjust flame adjustment
knob anywhere between HI and LO. Slide the selector
switch to the REMOTE position.
Note:
The burners may
light if hand-held remote ON button was on when selector
switch was last turned off. You can now turn the burners
on and off with the hand-held remote control unit.
REMOTE CONTROL OPERATION