Desa VMH26TPC Indoor Fireplace User Manual


 
www.desatech.com
113111-01C
16
Extension Cord
Use extension cord if needed. The cord must have
a three-prong, grounding plug and a three-hole
receptacle. Make sure cord is in good shape. It must
be heavy enough to carry the current needed. An
undersized cord will cause a drop in line voltage. This
will result in loss of power and overheating. Use a No.
16 AWG cord for lengths less than 50 feet.
ATTACHING WOOD BASE TO SOLID
FLOOR
For attaching base to solid floors (concrete or
masonry)
Note: Floor anchors and mounting screws are
in hardware package. The hardware package is
provided with fireplace.
1. Drill holes at marked locations using 5/16"
drill bit. For solid floors (concrete or ma
-
sonry), drill at least 1" deep.
2. Fold floor anchor as shown in Figure 21.
3. Insert floor anchor (wings first) into hole. Tap
anchor flush to floor.
4. Insert mounting screws through base and into
floor anchors.
5. Tighten screws until base is firmly fastened to
floor.
INSTALLATION
Continued
Figure 21 - Folding Anchor
CONNECTING TO GAS SUPPLY
WARNING: This appliance
requires a 45° male flare fitting
5/8"-18 UNF (Unified National Fine
Thread) inlet connection and the
flexible gas line provided.
WARNING: A qualified
service person must connect
fireplace to gas supply. Follow
all local codes.
CAUTION: Never connect pro-
pane/LP fireplace directly to the
propane/LP supply. This fireplace
requires an external regulator
(not supplied). Install the external
regulator between the fireplace
and propane/LP supply.
WARNING: Never connect natu-
ral gas fireplace to private (non-util-
ity) gas wells. This gas is commonly
known as wellhead gas.
For propane/LP units, installer must supply an
external regulator. The external regulator will
reduce incoming gas pressure. You must reduce
incoming gas pressure to between 11 and 14
inches of water. If you do not reduce incoming gas
pressure, fireplace regulator damage could occur.
Install external regulator with the vent pointing
down as shown in Figure 22. Pointing the vent
down protects it from freezing rain or sleet.
CAUTION: Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" or greater diameter to allow
proper gas volume to fireplace.
If pipe is too small, undue loss
of volume will occur.
Propane/LP
Supply Tank
External
Regulator
Figure 22- External Regulator with Vent
Pointing Down
Vent
Pointing
Down