Desa (V)CB36N(E) Indoor Fireplace User Manual


 
www.desatech.com
117437-01B24
LOGS
If you remove logs for cleaning, refer to In-
stalling Logs and Glowing Embers, page 18,
to properly replace logs.
Use a vacuum cleaner to remove any carbon
buildup on logs.
Replace log(s) if broken. See Replacement
Parts, page 34.
Replace ember material periodically as needed.
See Replacement Parts, page 34.
CLEANING AND
MAINTENANCE
Continued
VENTING SYSTEM
Conduct annual inspection of the venting system
following these guidelines:
1. Check areas of venting system that are ex-
posed to the weather corrosion (rust spots or
streaks and in extreme cases, holes). Have
these items replaced immediately by a quali-
ed service person.
2. Remove the vent cap and shine a ashlight
into vent. Remove any foreign material.
3. Check for evidence of excessive condensation.
Continuous condensation can cause corrosion
of caps, pipes and ttings and can be caused
by having excessive lateral runs, too many
elbows or exterior portions of the system being
exposed to cold weather.
4. Inspect joints to verify that no pipe section
or tting has been distributed and loosened.
Check mechanical supports such as wall straps
for rigidity.
SPECIFICATIONS
(V)CB36N
Maximum Input Rating: 18,000 Btu/hr
Gas Type: Natural
Orice Size (Main Burner): #45 DMS (0.082")
Ignition: Millivolt
Manifold Pressure: 3.5" w.c. (0.87 kPa)
Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)
(V)CB36P
Maximum Input Rating: 18,000 Btu/hr
Gas Type: Propane/LP
Orice Size (Main Burner): #55 DMS (0.052")
Ignition: Millivolt
Manifold Pressure: 10" w.c. (2.5 kPa)
Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa)
(V)CB36NE
Maximum Input Rating: 18,000 Btu/hr
Gas Type: Natural
Orice Size (Main Burner): #45 DMS (0.082")
Ignition: Electronic
Manifold Pressure: 3.5" w.c. (0.87 kPa)
Min. Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)
(V)CB36PE
Maximum Input Rating: 18,000 Btu/hr
Gas Type: Propane/LP
Orice Size (Main Burner): #55 DMS (0.052")
Ignition: Electronic
Manifold Pressure: 10" w.c. (2.5 kPa)
Min. Inlet Supply Pressure: 11" w.c. (2.7 kPa)
ALL MODELS
Fireplace Dimension HxWxD (Actual size of rebox measurements do not include
nailing anges or standoffs): 35.75" x 36.25" x 14.75" (90.8 x 92.1 x 37.5 cm)
Carton Dimension HxWxD: 36.75" x 38" x 16.25" (93.3 x 96.5 x 41.3 cm)