16
103310
INSTALLING
Continued
CONNECTING TO GAS SUPPLY
NOTICE
A qualified service person must connect heater to gas supply.
Follow all local codes.
WARNING ICON G 001
CAUTION
Never connect heater directly to the propane supply. This heater
requires an external regulator (not supplied). Install the external
regulator between the heater and propane supply.
Installation Items Needed
Before installing heater, make sure you have the items listed below.
external regulator (supplied by
installer, see above)
piping (check local codes)
sealant (resistant to LP gas)
manual shutoff valve *
test gauge connection *
sediment trap
tee joint
pipe wrench
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See Accessories, page 34.
Masonry Screw
Figure 12 - Attaching Base Assembly to Fireplace Floor
Bracket with
Screw Holes
Standard Oak
Log Chassis
Premium
Model Chassis
Masonry Screw
Bracket with
Screw Holes