Desa UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE Indoor Fireplace User Manual


 
11
101920
INSTALLING
Continued
INSTALLATION CLEARANCES
Note:
Clearances are
the same if
using optional
cabinet mantel
or built-in
installation.
Carefully follow the instructions below. This will ensure safe installation.
Minimum Wall and Ceiling Clearances (see Figure 7)
A. Clearances from the side of the fireplace opening to any combustible wall
should not be less than 16 inches.
B. Clearances from the top of the fireplace opening to the ceiling should not be
less than 42 inches.
WARNING ICON G 001
WARNING
Maintain the minimum clearances. If you can, pro-
vide greater clearances from floor, ceiling, and
adjoining wall.
Continued
Note:
The instructions below show installation using the cabinet mantel and hearth
base accessories. The hearth base accessory is optional for this installation. You can
install fireplace and cabinet mantel directly on the floor.
1. Assemble cabinet mantel and hearth base. Assembly instructions are included
with each accessory.
WARNING ICON G 001
WARNING
For conventional installation, it is recommended
you use the cabinet mantel or hearth base specified
in this manual. Surface clearances may not be
sufficient with other cabinet mantels and hearth
bases. This may create a fire hazard. See
Accesso-
ries,
page 31 for correct cabinet mantel and hearth
base.
CONVENTIONAL FIREPLACE INSTALLATION
Conventional installation of this fireplace involves installing fireplace along with the
cabinet mantel with hearth base accessories against a wall in your home. Follow the
instructions below to install the fireplace in this manner.
42"
16"
Figure 7 - Minimum Clearance to Wall and Ceiling
MINIMUM CLEARANCE
Side Wall - 16 "
Ceiling - 42"
Floor - 0"