www.desatech.com
113973-01A
6
4. When the gas on the face of the mesh screen
lights, continue to hold the valve button de
-
pressed for 30 seconds, then release.
5. If flame goes out, wait 5 minutes and repeat
the lighting procedure.
6. If heater will not light after repeated tries, do
not attempt to repair heater. Return heater to
nearest authorized service center or to manu
-
facturer of this product.
7. For dual burner models, repeat steps 1 through
4 to ignite the other burner.
8. After both burners or single burner, are lit,
turn the heater regulator knob to the desired
heat setting (LOW, MED, HI).
TO STOP HEATER
1. Securely close valve on the propane/LP
cylinder.
2. Turn the heater regulator knob to the "OFF"
position. Wait 15 minutes for the heater to cool
down before handling heater.
3. Always remove the heater from the propane/
LP tank after each use. Do not store the heater
while attached to propane/LP tank. Remove
the heater from the propane/LP tank by turn
-
ing the fuel connector nut clockwise. Always
store propane/LP tank outdoors. Never store
propane/LP tank in an enclosed area.
TO RESTART HEATER
1. Securely close valve at propane/LP cylinder.
2. Wait 5 minutes.
3. Restart following To Start Heater procedure,
page 5.
OPERATING INSTRUCTIONS
Continued
MAINTENANCE AND
STORAGE
1. Inspect heater before each use. Check connec-
tions for leaks. Apply mixture of liquid soap
and water to connections. Bubbles forming
show a leak that must be corrected. Correct
all leaks at once. Have heater inspected at least
annually by a qualified service person.
2. Before each use, check the soft "O" ring seat
at the bullnose of the POL fitting. If the "O"
ring is cut, scuffed, or otherwise damaged,
replace it with part number 6681.
3. Inspect hose/regulator assembly before each
use. If hose is highly worn or cut, replace.
3. Turn off the gas at the propane/LP gas supply
cylinder when the heater is not in use.
4. When the heater is to be stored, the connection
between the propane/LP gas supply cylinder
and the heater must be disconnected and the
cylinder removed from the heater and stored
out of doors and in accordance with Chapter
5 of the standard for Storage and Handling of
Liquefied Petroleum Gases ANSI/NFPA 58
.