Desa TC200V Electric Heater User Manual


 
103886-01F
3
3
For more information, visit www.desatech.com
For more information, visit www.desatech.com
SAFETY INFORMATION
UNPACKING
THEORY OF OPERATION
PRODUCT IDENTIFICATION
PROPANE SUPPLY
Keep propane tank(s) below 100° F.
Check heater for damage before each use. Do not use a dam-
aged heater.
Use only the hose and factory preset regulator provided with the
heater.
Check hose before each use of heater. If highly worn or cut,
replace with hose specified by manufacturer before using heater.
Do not alter heater. Keep heater in its original state.
Do not use heater if altered.
Locate heater on stable and level surface if heater is hot or
operating.
Not intended for use on finished floors.
Never block air inlet (bottom of shell) or air outlet (around top
of shell) of heater.
Do not leave heater unattended.
Keep children and animals away from heater.
Never move, handle, or service a hot or operating heater. Severe
burns may result. Wait 15 minutes after turning heater off.
To prevent injury, wear gloves when handling heater.
Never attach duct work to heater.
Turn off propane supply to heater when not in use.
Use only original replacement parts. This heater must use de-
sign-specific parts. Do not substitute or use generic parts. Im-
proper replacement parts could cause serious or fatal injuries.
SAFETY INFORMATION
Continued
PRODUCT IDENTIFICATION
UNPACKING
1. Remove all packing items applied to heater for shipment. Keep
plastic cover caps (attached to valve inlet and hose/regulator
assembly) for storage.
2. Remove all items from carton.
3. Check all items for shipping damage. If heater is damaged,
promptly inform dealer where you bought heater.
THEORY OF OPERATION
The Fuel System: The hose/regulator assembly attaches to the
propane gas supply. This provides fuel to the heater.
The Ignition System: The piezo ignitor lights the burner fuel supply.
The Automatic Control System: The automatic control valve shuts
off the heater if the flame goes out.
A
T
P
U
S
H
T
O
S
T
A
R
T
LO
HI
Hose/
Regulator
Assembly
Shell
Base
Piezo
Ignitor
Button
Ignitor
Electrode
Thermocouple
Valve Inlet
Control Knob
Top
Figure 1 - Product Identification
PROPANE SUPPLY
You must provide propane gas and tank(s).
Use this heater only with a propane vapor withdrawal supply
system. See Chapter 5 of the Standard for Storage and Handling of
Liquefied Petroleum Gas, ANSI/NFPA 58 and/or CAN/CGA B149.2.
Your local library or fire department will have this booklet.
The amount of propane gas ready for use from propane tanks varies.
Two factors decide this amount.
1. The amount of liquid propane gas in tank(s)
2. The temperature of tank(s)
The chart below shows the minimum number of 100-pound tanks
needed to run the heater. Connect tanks together with a manifold. Do
not operate this product with any tank smaller than 100 pounds.
Average Temp. (°F) Number Of
At Tank Location Tanks
60° 2
40° 2
32° 2
20° 2
10° 3
3
Less gas is vaporized at lower temperatures. Two or more 100-pound
tanks or one larger tank may be needed in colder weather. Your local
propane gas dealer will help you select the proper supply system.