7. Use only in well-vented areas. Before using
heater, provide at least a three-square-
foot opening of fresh, outside air for each
100,000 Btu/Hr (105,500 k/j) of rating.
8. Do not use heater outdoors or in occupied
dwellings.
9. Do not use heater in living or sleeping
quarters.
10. Keep appliance area clear and free from
combustible materials, gasoline, paint
thinner and other flammable vapors and
liquids. Dust is combustible. Do not use
heater in areas with high dust content.
11. If this heater is equipped with a thermo-
stat. Heater may start at anytime.
12. Check heater for damage before each
use. Do not use a damaged heater.
13. Use only propane/LP gas set up for vapor
withdrawal.
14.
Keep propane tank(s) below 100° F (38° C).
15. Do not use heater in a basement or below
ground level. Propane/LP gas is heavier
than air. If a leak occurs, propane/LP gas
will sink to the lowest possible level.
16. Use only the hose and factory regulator
provided with the heater.
17. Check hose before each use of heater. If
highly worn or cut, replace with hose speci-
ed by manufacturer before using heater.
18. Do not alter heater. Keep heater in its
original state.
19. Do not use heater if altered.
20. Keep heater at least 6 feet (1.8 m) from
propane/LP tank(s). Do not point heater at
propane/LP tank(s) within 20 feet (6.1 m).
21. Minimum heater clearances from com-
bustibles: Outlet: 8 Ft. (2.4 m), Sides: 2
Ft. (0.6 m), Top: 6 Ft. (1.8 m), Rear: 2 Ft.
(0.6 m).
22. Locate heater on stable and level surface
if heater is hot or running.
23. Keep children and animals away from
heater.
24. Turn off propane/LP supply and unplug
heater when not in use.
25. Never block air inlet (rear) or hot air outlet
(front) of heater.
26. Never move, handle or service a hot,
operating or plugged in heater.
SAFETy INFORMATION
Continued
27. Never attach duct work to front or rear of
heater.
28. Use only original replacement parts. This
heater must use design-specic parts.
Do not substitute or use generic parts.
Improper replacement parts could cause
serious or fatal injuries.
29. Do not use this product without leg and
foot assembly.
PRODUCT
IDENTIFICATION
Figure 1 - 55/85/125,000 Btu/Hr Models
Cord Cleat
Adjustable Foot
Burn Rate
Adjustment
Knob
Handle
Hot Air
Outlet
(Front)
Air Inlet
(Rear)
Figure 2 - 170,000 Btu/Hr Models
Cord Cleat
Adjustable
Foot
Burn Rate
Adjustment
Knob
Handle
Hot Air Outlet
(Front)
Air Inlet
(Rear)
Automatic
Gas Control
Valve Button
Thermostat
Knob