Desa REM200T Electric Heater User Manual


 
8
106068
PORTABLE FORCED AIR HEATER
200,000 BTU/HR
SERVICE
PROCEDURES
UPPER SHELL REMOVAL
1. Remove screws along each side of
heater using 5/16" nut-driver. These
screws attach upper and lower shells
together.
2. Lift upper shell off.
3. Remove fan guard.
FAN
IMPORTANT:
Remove fan from motor
shaft before removing motor from heater.
The weight of the motor resting on the fan
could damage the fan pitch.
1. Remove upper shell (see column 1).
2. Use 1/8" allen wrench to loosen set-
screw which holds fan to motor shaft.
3. Slip fan off motor shaft.
4. Clean fan using soft cloth moistened
with kerosene or solvent.
5. Dry fan thoroughly.
6. Replace fan on motor shaft. Place fan
hub flush with end of motor shaft (see
Figure 6).
7. Place setscrew on flat of shaft. Tighten
setscrew firmly (40-50 inch-pounds).
8. Replace fan guard and upper shell.
Fan
Setscrew
Motor
Shaft
Motor
Flush
Figure 6 - Fan Cross Section
Figure 5 - Upper Shell Removal
WARNING: Never service
heater while it is plugged in, op-
erating, or hot. Severe burns and
electrical shock can occur.
Upper
Shell
Fan
Guard
Figure 7 - Air Output, Air Intake, and Lint
Filters
Fan
Guard
Air Intake Filter
Air Output Filter
Filter End
Cover
Lint Filter
AIR OUTPUT, AIR INTAKE,
AND LINT FILTERS
1. Remove upper shell (see column 1).
2. Remove filter end cover screws using
5/16" nut-driver.
3. Remove filter end cover.
4. Replace air output and lint filters.
5. Wash or replace air intake filter (see
Preventative Maintenance Schedule,
page 6).
6. Replace filter end cover.
7. Replace fan guard and upper shell.
IMPORTANT:
Do not oil filters.
Screw