7
103909
OWNER’S MANUAL
SPECIFICATIONS
Input Rating (Btu/Hr) 150,000
Fuel Propane Vapor Only
Fuel Consumption
Liters (Gallons)/Hour 6 (1.6)
Kg (Pounds)/Hour 26.4 (7.0)
Supply Pressure To Regulator
Minimum (for purposes
of input adjustment) 69 (kPa) 10 psi
Maximum Tank Pressure
Regulator Outlet Pressure
(Factory Preset) 31.8 cm (12.5 in) WC
Manifold Pressure 24.9 cm (9.8 in) WC
Hot Air Output
(CFM Approx) 15.6 (550)
Motor 3,430 RPM, 1/8 HP
Electric Input 120 V/60 Hz
Amperage 2.2
Ignition Direct Spark, Interrupted Type
Ignitor Gap 3.3/3.8 mm (.13/.15 in)
Weight
Heater 11 kg (24 lb)
Shipping 16 kg (35 lb)
Size - L x W x H cm (in) 92.7 x 36.8 x 50.8 (36
1
/4 x 14
1
/2 x 20)
WIRING
DIAGRAMS
Electrical Connection Diagram
Power Cord
120 VAC
Motor
Green
Solenoid
Valve
On/Off
Switch
Safety
Control
G V VR ACR AC
Black
Black
White
Green
White
Black
Black
White
Blue
Blue
Blue
Blue
Insulated
Connector
Thermal
Switch
Orange
Green
Ignitor
Fuse (If Equipped)
Position of
Leads May
Vary
T
Electrical Ladder Diagram
Line
Neutral
Green or
Green/Yellow
White
Green
Black
Black
Fuse *
White
Motor
Blue
Blue
Blue
Blue
Green
Black
White
Orange
Ignitor
Thermal
Switch
Solenoid
Valve
Safety
Control
G V VR ACR AC
* If Equipped
Position of
Leads May
Vary
TT