www.desatech.com
119426-01A 17
INSTALLATION
Continued
Figure 18 - Checking Gas Joints
(Propane/LP Only)
Thermostat Gas
Valve or Control
Valve Location
Propane/LP
Supply Tank
Equipment
Shutoff Valve
Gas Meter
Figure 19 - Checking Gas Joints (Natural
Gas Only)
Thermostat Gas
Valve or Control
Valve Location
Equipment
Shutoff Valve
INSTALLING OPTIONAL REMOTE
ACCESSORIES
Installing Remote Receiver
Remote control accessories are available sepa-
rately (see Accessories, page 42).
1. If unit is already installed in replace, continue
with these instructions. If unit has not been
installed in replace, go to step 6 and continue
installation of remote accessory.
WARNING: Turn off heater
and let cool before handling any
part of heater. Make sure gas is
turned of to unit.
2. Carefully remove logs and set aside.
3. Locate mounting screws on sides of heater
base assembly and remove screws. Set screws
aside for reinstallation.
4. Disconnect gas line from heater base as shown
in Figure 11 or 12, page 13.
WARNING: A qualied ser-
vice person must connect and
disconnect gas to heater. Follow
all local codes.
5. Remove heater base from replace.
6. Install receiver bracket to base with phillips
screws provided in hardware kit as shown in
Figure 20.
7. Disconnect jumper wire from control valve at
TPTH and TH locations (see Figure 21).
8. Install remote receiver into receiver bracket
using pads and push button clips provided
with receiver (see Figure 22).
Figure 22 - Installing Remote Receiver
Push
Button
Clips
Bracket
Battery
Clip
9-Volt Battery
Terminal
Wires
Pad
Figure 21 - Disconnecting Jumper Wire
From Control Valve
Jumper
Wire
Control Valve
Figure 20 - Installing Remote Receiver
Bracket
Remote Receiver Bracket
Phillips
Screws