Desa PH70EDI Air Conditioner User Manual


 
18
099800
Pump Rotor
(Procedure if rotor is binding)
1. Remove upper shell (see
page 10).
2. Remove lter end cover
screws using 5/16" nut-
driver.
3. Remove lter end cover
and air lters.
4. Remove pump plate
screws using 5/16" nut-
driver.
5. Remove pump plate.
6. Remove rotor, insert, and
blades.
7. Check for debris in pump.
If debris is found, blow
out with compressed air.
8. Install insert and rotor.
9. Check gap on rotor.
Adjust to .076/.101 mm if
needed (see Figure 33).
Note:
Rotate rotor one
full turn to insure the gap is
.076/.101 mm at tightest
position. Adjust if needed.
10. Install blades, pump plate,
air lters, and lter end
cover.
11. Replace fan guard and
upper shell.
12. Adjust pump pressure (see
page 14).
Note:
If rotor is still binding,
proceed as follows.
13. Perform steps 1 thru 6
above.
14. Place ne grade sandpaper
(600 grit) on at surface.
Sand rotor lightly in
“figure 8 motion four
times (see Figure 34).
15. Reinstall insert and rotor.
16. Perform steps 10 thru 12
above.
Figure 31 - Rotor Location, 30/70,000 BTU/Hr Models
Sandpaper
Figure 34 - Sanding Rotor
.076/.101 mm Gap
Measured With
Feeler Gauge
Rotor
Gap Adjusting
Screw
Gap
Adjusting
Screw
Blade
Figure 33 - Gap Adjusting
Screw Locations
Figure 32 - Rotor Location, 90/150,000 BTU/Hr Models
150 ROTOR PFA/P 059
Insert
Blade
Rotor
Pump
Plate
Filter End
Cover
Air
Intake
Filter
Air
Output
Filter
50 ROTOR
PFA/P 056
Pump
Plate
Insert
Rotor
Blade
Filter End
Cover
Air
Intake
Filter
Air Output
Filter
Fan Guard
(90,000 BTU/Hr
Model Shown)
Fan Guard
(90,000 BTU/Hr
Model Shown)