www.desatech.com
108805-01C4
2. After lling in the data required on the
conversion information label, afx it to
the oor of the appliance where it is easily
seen when the control cover is removed
(see Figure 9).
CONVERSION INFORMATION LABEL
This appliance was converted on
(name and address of organization making
this conversion), which accepts the
responsibility that this conversion has been
properly made.
Day Month Year
– – to gas
with Kit No.
by
106080-01
Figure 9 - Conversion Information Label
VENTED GAS FIREPLACE
Conversion Kit Model
Type of Gas
Previous Model #
Figure 8 - Print Previous Model Number
on Conversion Labels
PILOT ORIFICE CONVERSION
1. Remove pilot hood assembly by pulling up
until it disengages from barrel. DO NOT
remove barrel clip (see Figure 10).
2. Remove pilot orice from inside barrel
using a 5/32" allen wrench to unscrew the
orice.
3. Replace pilot orifice with LP orifice
supplied with this kit. The number 30 is
stamped on the sleeve for identication.
Insert small end of new pilot orice into
barrel and thread until tight with allen
wrench.
4. Line up notch on pilot hood assembly
to positioning tab on barrel receiver and
snap back into position.
IMPORTANT: Be careful not to bend or
kink aluminum tubing during conversion.
Make sure pilot hood and orice are prop-
erly mated and aligned after nishing this
conversion.
Figure 10 - Converting Pilot Orice
Pilot Hood
Pilot Orice
Barrel Clip
Pilot Bracket
5/32" Allen
Wrench