Desa NZ118 Electric Heater User Manual


 
www.desatech.com
29118621-01B
SPECIFICATIONS
NZ100, NZ104, NZ116
Natural Gas
18,000 Btu/hr
Piezo Ignition
Pressure Regulator Setting: 6" W.C.
Inlet Gas Pressure* (in. of water):
Maximum - 10.5", Minimum - 7"
Average Heater Weight: 22 lb (10 kg)
Average Shipping Weight: 25.5 lb (11.6 kg)
NZ101, NZ105, NZ117
Propane/LP Gas
16,000 Btu/hr
Piezo Ignition
Pressure Regulator Setting: 8" W.C.
Inlet Gas Pressure* (in. of water):
Maximum - 14", Minimum - 11"
Average Heater Weight: 22 lb (10 kg)
Average Shipping Weight: 25.5 lb (11.6 kg)
NZ102, NZ106, NZ118
Natural Gas
30,000 Btu/hr
Piezo Ignition
Pressure Regulator Setting: 6" W.C.
Inlet Gas Pressure* (in. of water):
Maximum - 10.5", Minimum - 7"
Average Heater Weight: 29 lb (13.2 kg)
Average Shipping Weight: 33 lb (15 kg)
NZ103, NZ107, NZ119
Propane/LP Gas
26,000 Btu/hr
Piezo Ignition
Pressure Regulator Setting: 8" W.C.
Inlet Gas Pressure* (in. of water):
Maximum - 14", Minimum - 11"
Average Heater Weight: 29 lb (13.2 kg)
Average Shipping Weight: 33 lb (15 kg)
Wiring Diagram
Electrical Ladder Diagram
Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).
* For purposes of input adjustment.
WIRING DIAGRAMS
WARNING: Never attempt to
service heater while it is plugged
in, operating, or hot. Burns and
electrical shock could result.
Only a qualied service person
should service or repair heater.
CAUTION: Label all wires
prior to disconnection when
servicing controls. Wiring errors
can cause improper and dan-
gerous operation. Verify proper
operation after servicing.