Desa NTH70-2 Electric Heater User Manual


 
25
105787
OWNER’S MANUAL
Output Rating
(Btu/Hr\kw) 35,000(10) 50,000(15) 70,000(20) 100,000(30) 150,000(44)
Fuel Use Only Kerosene or No. 1 Fuel Oil
Fuel Tank Capacity
(U.S. Gal./Liters) 3.0/11.4 5.0/18.9 5.0/18.9 9.0/34 13.5/51.1
Fuel Consumption
(Gal. Per Hr./
Liters Per Hr.) .28/1.1 .37/1.40 .52/1.97 .79/3.0 1.1/4.1
Electric Requirements 240 V/50 Hz (Same All Models)
Amperage
(Normal Run) .8 1.0 1.0 1.2 1.2
Hot Air Output
(CFM/CMM) 140/4 205/5.8 225/6.4 425/12 500/14.2
RPM 1425 2850 2850 2850 2850
SPECIFICATIONS
WIRING DIAGRAM
(7)
(2)(1)
(8)
(3) (4) (6)
(N)
(5)
1a
1
1b
Power Plug
240 V/50Hz
Ignition Control
Green-Yellow
Green-Yellow
Ignitor
Photocell
White
White
Red
Brown/White
Brown
Blue
Blue
Blue
Blue
ON/Off Switch
Black
Black
Motor