OWNER’S MANUAL
OPERATION
WARNING: Review and un-
derstand the warnings in the
Safety Information
section, page
2. They are needed to safely op-
erate this heater. Follow all local
codes when using this heater.
TO START HEATER
1. Follow all ventilation and safety infor-
mation.
2. Fill fuel tank with kerosene or No. 1
fuel oil.
3. Attach fuel cap.
4. Plug power cord of heater into standard
240 volt/50 hertz, grounded (earthed)
outlet. Use an extension cord if needed.
Use only a three-prong, grounded
(earthed) extension cord.
Figure 5 - ON/OFF Switch, 35/50/70,000
Btu/Hr Models
Figure 6 - ON/OFF Switch, 100/150,000
Btu/Hr Models
THEORY OF
OPERATION
The Fuel System: The air pump forces
air through the air line. The air is then
pushed through the burner head nozzle. This
air causes fuel to lift from the tank. A fine
mist of fuel is sprayed into the combustion
chamber.
The Air System: The motor turns the fan.
The fan pushes air into and around the
combustion chamber. This air is heated and
provides a stream of clean, hot air.
The Ignition System: The ignition con-
trol assembly provides power to the ignitor.
This ignites the fuel/air mixture in the com-
bustion chamber.
The Flame-Out Control System: This sys-
tem causes the heater to shut down if the
flame goes out.
EXTENSION CORD WIRE
SIZE REQUIREMENTS
Up to 30.5 meters (100 feet) long, use 1.0
mm
2
(16 AWG) conductor
30.6 to 61 meters (101 to 200 feet) long, use
1.5 mm
2
(14 AWG) conductor
Push ON/OFF switch to ON (|) position and
heater should start in 5 seconds. If ON/OFF
switch light does not come on or heater does
not start, see Troubleshooting (pages 6 and 7).
TO STOP HEATER
Push ON/OFF switch to OFF (O)position.
TO RESET HEATER
1. Push ON/OFF switch to OFF (O) posi-
tion and wait 10 seconds (2 minutes if
heater has been running).
2. Repeat steps under To Start Heater.
Figure 4 - Cross Section Operational View
|
O
ON/OFF Switch
with Light
|
O
ON/OFF Switch
with Light
Clean
Heated
Air Out
Fuel
Filter
Air Line
To Burner
Air
Output
Filter
Air Pump
Air Intake
Filter
Cool
Air
In
Fan
Combustion Chamber
Ignitor
Motor
Ignition Control
Assembly
Air For Fuel System
Air For Combustion
And Heating
Fuel
Nozzle
Fuel