23
101308
OPERATING
HEATER
Manually-Controlled
Models
Continued
5. Press in control knob and turn counterclockwise
C-clockwise
to the PILOT position.
Keep control knob pressed in for five (5) seconds (see Figure 22).
Note:
You may be running this heater for the first time after hooking up to gas
supply. If so, the control knob may need to be pressed in for 30 seconds. This will
allow air to bleed from the gas system.
• If control knob does not pop out when released, contact a qualified service
person or gas supplier for repairs.
6. With control knob pressed in, press and release ignitor button. This will light pilot.
The pilot is attached to the front burner. If needed, keep pressing ignitor button
until pilot lights.
Note:
If pilot does not light, contact a qualified service person or gas supplier for
repairs. Until repairs are made, light pilot with match. To light pilot with match,
see Manual Lighting Procedure, below.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,
release control knob.
Note:
If pilot goes out, repeat steps 3 through 7.
Shutting Off Heater
1. Press in and turn control knob clockwise
Clockwise
to the PILOT position.
2. Press in control knob and turn clockwise
Clockwise
to the OFF position.
Shutting Off Burners Only (pilot stays lit)
1. Press in and turn control knob clockwise
Clockwise
to the PILOT position.
MANUAL LIGHTING PROCEDURE
1. Follow steps 1 through 5 under Lighting Instructions, page 22.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds, release control knob. Now follow step 8, above.
TO TURN OFF GAS TO APPLIANCE
8. Turn control knob counterclockwise
C-clockwise
to the LOW position. The front
burner should light. Set control knob to either HIGH, MEDIUM, or LOW. To turn
control knob from LOW to a higher setting, press in the control knob and turn
counterclockwise
C-clockwise
. On LOW and MEDIUM positions, only front burner
operates. On HIGH position, front and rear burner operates.
WARNING ICON G 001
WARNING
HIGH, MEDIUM, and LOW are locked positions. You must press in
control knob before turning it from these positions. Do not operate
heater between locked positions or sooting could occur.
WARNING ICON G 001
CAUTION
Do not try to adjust heating levels by using the manual shutoff valve.
Figure 23 - Pilot
Thermocouple
Ignitor Electrode
Pilot Burner