Desa LFP33PRA Indoor Fireplace User Manual


 
17
107064
OWNER’S MANUAL
O
F
F
P
I
L
O
T
O
N
L
O
I
H
ON
OFF
REMOTE
Figure 39 - Setting the Selector Switch, Control Knob, and Flame
Adjustment Knob for Remote Operation
Selector Switch in Remote
Position(Optional Remote Control)
Control Knob in
On Position
Flame Adjustment Knob
WARNING: Make sure the se-
lector switch is in the OFF posi-
tion when you are away from home
for long periods of time. Heater
will come on automatically with
selector switch in the ON position.
OPERATING
FIREPLACE
Continued
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
to the OFF position.
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Re-
mote: Set selector switch in the OFF
position to keep from draining the
battery.
Shutting Off Burners Only (pilot
stays lit)
You may shut off the burners and keep
the pilot lit by doing one of the following:
Turn control knob clockwise
to the PILOT position.
Use remote control manual OFF button.
Set selector switch in the OFF position.
MANUAL LIGHTING
PROCEDURE
Thermostat Control Operation
The thermostat control setting on the
remote control unit can be set to any
comfort level between HI and LO. The
burners will turn on and off automati-
cally to maintain the comfort level you
select. The ideal comfort setting will vary
by household depending upon the amount
of space to be heated, the output of the
central heating system, etc.
1. Follow steps 1 through 6 under Light-
ing Instructions, page 16.
2. Depress control knob and light pilot
with match.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 9, column 3, page 16.
OPTIONAL REMOTE
OPERATION
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See
Lighting
Instructions
on page 16.
Note:
The receiver and hand held remote
control must be purchased separately (see
Accessories, pages 24 and 25). Follow
instructions included with the remote control.
Figure 38- Pilot
Ignitor
Electrode
Pilot Burner
After lighting, let pilot flame burn for
about one minute. Turn control knob to
ON position. Adjust flame adjustment
knob anywhere between HI and LO. Slide
the selector switch to the REMOTE posi-
tion.
Note:
The burners may light if hand-
held remote ON button was on when
selector switch was last turned off. You
can now turn the burners on and off with
the hand-held remote control unit. Follow
instructions supplied with the remote con-
trol for additional features.
IMPORTANT:
Do not leave the selector
switch in the REMOTE position when the
pilot is not lit. This will drain the battery.
IMPORTANT:
Be sure to press the ON/
OFF buttons on the hand-held remote
control unit for up to 3 seconds to assure
proper operation.
IMPORTANT:
The thermostat is built
into the hand-held remote. The remote
should be kept several feet from the fire-
place and should be pointed towards the
fireplace. If placed too close to the fire-
place, the remote will sense the room is
too hot and turn the fireplace off.
Continued
Locate the blower switch by opening lower
louver on fireplace. Blower switch is lo-
cated at lower right inside louver door.
The GA3650TA Series thermostat-con-
trolled blower has a variable speed con-
trol with an ON/OFF switch. The blower
will start when the thermostat senses a
sufficient increase in firebox temperature.
The GA3750 Series variable speed blower
also has an ON/OFF switch built into the
variable speed control.
Note for GA3650TA Series Only:
If
you are using GA3650TA blower, your
fireplace and blower will not turn on and
off at the same time. The fireplace may
run for several minutes before the blower
turns on. After the heater modulates to
the pilot position, the blower will con-
tinue to run. The blower will shut off after
the firebox temperature decreases.
Note:
It is safe to operate fireplace with
blower turned off. However, the blower helps
distribute heated air from the fireplace.
Follow installation instructions included
with the blower accessory.
OPTIONAL BLOWER
OPERATION