Desa INTERNATIONAL UNVENTED (VENT-FREE) GAS LOG HEATER Electric Heater User Manual


 
108114
For more information, visit www.desatech.com
For more information, visit www.desatech.com
19
19
Note:
Home owners generally prefer to operate their heater
with the chimney damper closed. This will put all the heat into
the room. However, there may be times you will desire the full
flames of the Hi heat setting but will find the heat output
excessive. You can open the chimney damper (if you have one)
fully or partially to release some of the heat.
WARNING: Damper handle will be hot if heater has
been running.
1. STOP! Read the safety information on page 18, column 2.
2. Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise
Clockwise
to the OFF position.
4. Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information, page 18, column 2. If
you don’t smell gas, go to the next step.
5. Turn control knob counterclockwise to the PI-
LOT position. Press in control knob for five (5) seconds
(see Figure 34).
Note:
You may be running this heater for the first time
after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.
6. With thermostat control knob pressed in, press and release
ignitor button. This will light pilot. The pilot is attached to
the front burner. If needed, keep pressing ignitor button
until pilot lights.
Note:
If pilot does not stay lit, contact a qualified service
person or gas supplier for repairs. Until repairs are made,
light pilot with match. To light pilot with match, see Manual
Lighting Procedure on page 20.
7. Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
If control knob does not pop out when released, contact
a qualified service person or gas supplier for repairs.
Note:
If pilot goes out, repeat steps 3 through 7. This heater
has a safety interlock system. Wait one (1) minute for sys-
tem to reset before lighting pilot again.
8. Turn control knob counterclockwise to desired
heating level. The front burner should light. Set control
knob to any heat level between HI and LO.
9. To light the rear yellow flame burner, push in and turn
rear burner control knob counterclockwise to the
ON position.
OPERATING HEATER
Continued
Figure 34 - Control Knob(s) and Ignitor Button Locations
Models: VGX24NT, VGX24PT, VGX30NT, VGX30PT, CGX3924NT,
CGX3924PT, CGX3930NT and CGX3930PT
Ignitor Button
Control Knob
Rear Burner
Control Knob
Models: LGX3924NT and LGX3924PT
Ignitor Button
Control Knob
Figure 35 - Pilot (Propane/LP)
TO TURN OFF GAS TO APPLIANCE
CAUTION: Do not try to adjust heating levels by
using the equipment shutoff valve.
Shutting Off Heater
1. Turn control knob clockwise to the OFF position.
2. Turn rear burner control knob clockwise to the
OFF position.
Shutting Off Burners Only (pilot stays lit)
1. Turn control knob clockwise to the PILOT position.
2. Turn rear burner control knob clockwise to the
OFF position.
OPERATING HEATER (THERMOSTAT-CONTROLLED MODELS)
Lighting Instructions (Cont.)
To Turn Off Gas To Appliance
Ignitor Electrode
Pilot Burner
Thermocouple
Figure 36 - Pilot (Natural)
Ignitor
Electrode
Pilot Burner
Thermocouple