Desa HRB3624 Electric Heater User Manual


 
www.desatech.com
119426-01A 31
TROUbLESHOOTING
Continued
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor’s phone. Fol-
low the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint,
paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These
fumes may mix with combustion air and create odors. These odors will disappear over time.
POSSIBLE CAUSE
1.
Heater burning vapors from paint,
hair spray, glues, cleaners, chemi-
cals, new carpet, etc. (See IM-
PORTANT statement above)
2. Low fuel supply (propane/LP
only)
3. Gas leak. See Warning
statement at top of page
1. Not enough fresh air is avail-
able
2. Low line pressure
3.
ODS/pilot is partially clogged
1. Gas leak. See Warning
statement at top of page
2. Control valve or gas control
defective
1. Foreign matter between con-
trol valve and burner
2. Gas leak. See Warning
statement at top of page
1. Thermostat sensing bulb needs
to be repositioned (Thermo-
stat-Controlled Models Only)
2. Hand-held remote control is
too close to heater (Remote-
Ready Models Only)
REMEDY
1. Open window to ventilate
room. Stop using odor caus-
ing products while heater is
running
2. Rell supply tank (propane/LP
only)
3. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 16)
1. Open window and/or door for
ventilation
2. Contact local natural or pro-
pane/LP gas company
3. Clean ODS/pilot (see Cleaning
and Maintenance, page 26)
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 16)
2. Replace control valve or gas
control
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 16)
1. Reposition thermostat sensing
bulb (see Optional Positioning
of Thermostat Sensing Bulb,
page 32)
2. Move hand-held remote con-
trol unit farther away from the
heater
OBSERVED PROBLEM
Heater produces unwanted
odors
Heater shuts off in use (ODS
operates)
Gas odor even when control
knob is in OFF position
Gas odor during combustion
Log set cycles to pilot, but room
temperature drops to a lower
than ideal level before log set
comes back on