Desa GWN20 Electric Heater User Manual


 
www.desatech.com
107884-01H
17
Figure 22 - Pilot (actual pilot may vary)
6. With control knob pressed in, push down
and release ignitor button. This will light
pilot. The pilot is attached to the front of
burner. The pilot is attached to the front of
the burner. If needed, keep pressing igni-
tor button until pilot lights.
Note:
If pilot does not stay lit, refer to
Troubleshooting, pages 20 through 23. Also
contact a qualified service person or gas
supplier for repairs. Until repairs are made,
light pilot with match. To light pilot with
match, see Manual Lighting Procedure.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop up when re-
leased, contact a qualified service person
or gas supplier for repairs.
Note:
If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one (1) minute before
lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The main burner
should light. Set control knob to any heat
level between 1 and 5.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
OPERATING HEATER
Continued
Ignitor Electrode
Pilot Burner
Thermocouple
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise to the
OFF position.
2. Turn off all electric power to the appliance
if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise to the PI-
LOT position.
THERMOSTAT CONTROL
OPERATION
The thermostatic control used on these models
differs from standard thermostats. Standard
thermostats simply turn on and off the burner.
The thermostat used on this heater senses the
room temperature. The thermostat adjusts the
amount of gas flow to the burner. This increases
or decreases the burner flame height. At times
the room may exceed the set temperature. If so,
the burner will shut off. The burner will cycle
back on when room temperature drops below
the set temperature. The control knob can be
set to any heat level between 1 and 5. Selecting
the 5 setting will cause the burner to remain fully
on without modulating down in most cases.
Note:
The thermostat sensing bulb measures
the temperature of air near the heater cabinet.
This may not always agree with room tempera-
ture (depending on housing construction, instal-
lation location, room size, open air tempera-
tures, etc.). Frequent use of your heater will let
you determine your own comfort levels.
MANUAL LIGHTING
PROCEDURE
1. Remove front panel (see Figure 7, page 9).
2. Follow steps 1 through 5 under Lighting In-
structions, pages 16 and 17.
3. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob. Now follow step 8, under Light-
ing Instructions, pages 16 and 17.
5. Replace front panel.