Desa GVR35PA Water Heater User Manual


 
27
100791
WARNING ICON G001
WARNING
Turn off and unplug heater and let cool before servicing.
Unless you need gas supply for testing, shut off manual
shutoff valve before servicing. Only a qualified service
person should service and repair heater and venting
system.
WARNING ICON G001
CAUTION
Never use a wire, needle, or similar object to clean pilot.
This can damage pilot.
TROUBLE-
SHOOTING
Note:
All troubleshooting items
are listed in order of operation.
POSSIBLE
CAUSE
1. Incorrect spark gap.
2. Ignitor electrode posi-
tioned wrong.
3. Ignitor electrode broken.
4. Ignitor electrode not con-
nected to ignitor cable.
5. Ignitor cable pinched or
wet.
6. Piezo ignitor nut is loose.
7. Broken or frayed ignitor
cable.
8. Loose ignitor cable.
9. Bad piezo ignitor.
1. Gas supply turned off or
manual shutoff valve
closed.
2. Control knob not in
PILOT position.
3. Control knob not
pressed in while in
PILOT position.
4. Air in gas lines when
installed.
5. Depleted gas supply.
6. Pilot is clogged.
7. Gas regulator setting is
not correct.
REMEDY
1. Adjust spark gap to 1/16".
2. Replace ignitor.
3. Replace ignitor.
4. Reconnect ignitor cable.
5. Free ignitor cable if
pinched by any metal or
tubing. Keep ignitor
cable dry.
6. Tighten nut holding piezo
ignitor to heater cabinet.
Nut is located inside
heater cabinet at top.
7. Replace ignitor cable.
8. Reconnect ignitor cable.
9. Replace piezo ignitor.
1. Turn on gas supply or
open manual shutoff
valve.
2. Turn control knob to
PILOT position.
3. Press in control knob
while in PILOT position.
4. Continue holding down
control knob. Repeat
igniting operation until
air is removed.
5. Contact local propane
gas company.
6. Clean pilot (see Clean-
ing and Maintenance,
page 26) or replace pilot
assembly.
7. Replace control valve.
OBSERVED
PROBLEM
When ignitor button
is pressed, there is no
spark at pilot.
When ignitor button
is pressed, there is
spark at pilot but no
ignition.
Continued