INSTALLING HOOD TO
MANUFACTURED FIREPLACE
WARNING: Many manufac-
tured fireplaces have louver open-
ings for ventilation. Do not cover
any louver openings with fireplace
hood. Do not mount fireplace hood
above any louver openings. Only
mount fireplace hood below louver
openings. Covering louver open-
ings or mounting fireplace hood
above louver openings will cause
the fireplace to overheat and could
cause property damage, personal
injury, or death due to fire.
CAUTION: Brass-plated
hood may tarnish due to heat if
you mount it too low. Make sure
the bottom of hood is at least 17
inches above the bottom of fire-
place (see Figure 11). If installa-
tion height is less than 17 inches,
use the GA6050 flat-black hood.
You may need to alter or discard the mounting
brackets to install the fireplace hood to the manu-
factured fireplace.
Figure 10 - Hood Placement for Masonry
Fireplace
3. Remove mounting brackets and drill a 5/32
inch diameter hole into fireplace lintel at each
marked location.
4. Use the masonry screws provided to fasten
brackets to lintel (see Figure 9, page 2).
5. Slide hood over mounting brackets (see
Figure 10).
17" Min.
Fireplace
Cross
Section
Mounting Brass Hood On Fireplace
Surface
Fireplace
Mounting Brass Hood Inside Fireplace
Opening
Fireplace
Brass Fireplace
Hood
21" Minimum Fireplace Opening Required
to Maintain 17" Minimum From Bottom of
Hood to Bottom of Fireplace
Fireplace
Cross
Section
Figure 11 - Installing Brass-Plated Hood
Installing Above Manufactured Fireplace
Opening
1. Cut mounting bracket off at point "A" (see
Figure 6, page 2).
2. Tape mounting bracket to fireplace housing.
Make sure top of bracket is six inches above
fireplace opening (see Figure 12).
3. Mark screw locations through slots in mount
-
ing bracket.
Figure 12 - Installing Hood Above
Opening on Manufactured Fireplace
6"
Manufactured
Fireplace
Hood
Mounting
Brackets
Brass
Fireplace
Hood
Fireplace Opening
Mounting
Brackets