LOCAL CODES
Install and use fireplace with care. Follow all local codes. In the
absence of local codes, use the latest edition of The National Fuel
Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note:
Where listed vented decorative logs are required, thermostat
operation is not permitted.
1. With utility knife, cut the carton all the way around above the
staples on the bottom tray. Lift the carton off the heater. Re-
move packing.
Note:
The hood is located in the packing on
the right hand side of the heater front. Lift the heater off the
bottom tray.
2. Locate two screws above top corners of the fireplace screen.
Remove and discard these screws. Lift fireplace screen up and
pull out to remove.
3. Remove protective packaging applied to logs, log base assem-
bly, and fireplace.
4. Remove fireplace hood from carton insert.
5. Check all items for any shipping damage. If damaged, promptly
inform dealer where you bought fireplace.
UNPACKING
CAUTION: Do not remove the data plates attached
to the heater base assembly. The data plates contain
important warranty and safety information.
AIR FOR COMBUSTION AND
VENTILATION
Today’s homes are built more energy efficient than ever. New mate-
rials, increased insulation, and new construction methods help reduce
heat loss in homes. Home owners weather strip and caulk around
windows and doors to keep the cold air out and the warm air in. During
heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home
needs to breathe. Fresh air must enter your home. All fuel-burning
appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances
draw air from the house to operate. You must provide adequate fresh
air for these appliances. This will insure proper venting of vented
fuel-burning appliances.
WARNING: This heater shall not be installed in a
confined space or unusually tight construction un-
less provisions are provided for adequate combus-
tion and ventilation air. Read the following instruc-
tions to insure proper fresh air for this and other
fuel-burning appliances in your home.
LOCAL CODES
UNPACKING
PRODUCT FEATURES
AIR FOR COMBUSTION AND VENTILATION
PRODUCT FEATURES
OPERATION
This vent-free fireplace is clean burning. It requires no outside
venting. There is no heat loss out a vent or up a chimney. Heat is
generated by both realistic flames. When used without the blower, the
fireplace requires no electricity making it ideal for emergency backup
heat. This heater is designed for vent-free operation. It has been tested
and approved to ANSI Z21.11.2 standard for unvented heaters. State
and local codes in some areas prohibit the use of vent-free heaters.
SAFETY DEVICE
This fireplace has a pilot with an Oxygen Depletion Sensing (ODS)
safety shutoff system. The ODS/pilot is a required feature for vent-
free room heaters. The ODS/pilot system shuts off the fireplace if
there is not enough fresh air.
PIEZO IGNITION SYSTEM
This fireplace has a piezo ignitor. This system requires no matches,
batteries, or other sources to light fireplace.
OPTIONAL REMOTE CONTROL UNITS
There are four optional remote controls that can be purchased
separately for this log heater:
• wall switch
• wall thermostat
• hand-held ON/OFF remote
• hand-held thermostat remote
See Accessories, pages 34 and 35.
OPTIONAL BLOWER ASSEMBLY (GA3700
SERIES & GA3700TA SERIES)
This fireplace accepts an optional blower assembly (not included).
The GA3700TA Series blower operates thermostatically and fea-
tures a variable speed control. The GA3700 Series blower operates
manually and also features a variable speed control. The blower
circulates heated air from the fireplace into the room. See Accesso-
ries, pages 34 and 35.