Desa E32LH Indoor Fireplace User Manual


 
www.desatech.com
111076-01F 7
INSTALLATION
Continued
LAMPS AND LAVA ROCK
Before operating replace, lamp bulbs must
be inspected and lava rock may be added if
desired.
1. Lift log bed off hearth base to gain access
to lamp xtures (log bed is attached with
contact magnets).
2. Turn on power to light circuit and check
that all bulbs are operating. Bulb place-
ment front left to right are red, yellow and
orange (see Figure 9).
Note: If bulbs need replacing, see Replac-
ing Light Bulbs, page 16. Be careful not to
tear or damage reective strips. If they have
come loose, ends can be easily reattached or
replaced at support brackets. See Replacing
Reective Ribbons, page 21.
FEATURES AND OPERATION
Figure 9 - Bulb Placement
Red
Yellow
Orange
Log Bed
Figure 10 - Accessing Controls
Grate
Viewing Panel
Screen
3. Center log bed over opening between
viewing panel screen and grate.
4. Cover remaining hearth area with 1/4" of
lava rock (provided), if desired.
This electronic fireplace series features
a random ame effect, and a realistic log
bed with glistening embers that can be ad-
justed for ame speed and light intensity.
E36/32LH models have a circulating heater,
rated at 1100 Watts. Models E36/32LB and
E36/32LBH include a hand detailed, textured,
red-brick lining.
Access controls by pulling two handle tabs
of upper louver until panel releases from
magnetic catches and swings down to open
position (see Figure 10).
Figure 11, page 8, shows control layout for
heater equipped models with main power
switch to ame controls and heater power
switch (when equipped) to heating unit. This
allows independent and efcient operation of
both features.
Once main power is turned on, ame speed
and brightness may be turned on and adjusted
independently.