Desa DVFH34 Indoor Fireplace User Manual


 
26
106394
DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)
DVFH34, DVFH34P
O
F
F
P
I
L
O
T
O
N
L
O
I
H
ON
OFF
REMOTE
ON
OFF
OPERATING
FIREPLACE
Continued
Blower Control Knob
(Optional Accessory)
Variable
Control Knob
Selector Switch in
Remote Position
Gas Control
Knob in ON
Position
Figure 57 - Setting the Selector Switch,
Gas Control Knob, and Variable Control
Knob for Remote Operation
GHRC Series Operation:
2a. Press the ON/OFF button to turn the
burners on and off. When turning
burners off, the pilot will remain lit.
GHRCTA Series Operation:
2b. Press the AUTO/ON/OFF button on
the hand-held remote control (see Fig-
ure 58). The lights to the left of the
button will show AUTO, ON, or OFF.
In the ON mode, the burners will
ignite. The heater is in manual
mode when ON is lit.
In the AUTO mode, the thermostat
in the hand-held remote unit con-
trols the room temperature. To in-
crease the room temperature, press
the top arrow of the TEMP button.
To lower the room temperature,
press the bottom arrow of the
TEMP button. At higher settings
the heater will run longer.
1. After lighting, let pilot flame burn for
about one minute. Turn gas control
knob to ON position. Adjust variable
control knob anywhere between HI
and LO. Slide the selector switch to
the REMOTE position (see Figure
57).
Note:
The burners may light if
hand-held remote ON button was on
when selector switch was last turned
off. You can now turn the burners on
and off with the hand-held remote
control unit.
IMPORTANT
: Do not leave the selec-
tor switch in the REMOTE position
when the pilot is not lit. This will
drain the battery.
IMPORTANT:
Be sure to press the
ON/OFF buttons on the hand-held
remote control unit for up to 3 sec-
onds to assure proper operation.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See
Lighting
Instructions
on page 25.
OPTIONAL REMOTE
OPERATION
Thermostat Control Operation
(Optional GHRCTA Series Only) The
thermostat control setting on the remote
control unit can be set to any comfort
level between WARMER and COOLER.
The burners will turn on and off auto-
matically to maintain the comfort level
you select. The ideal comfort setting will
vary by household depending upon the
amount of space to be heated, the output
of the central heating system, etc.
Note:
All remote control accessories must
be purchased separately (see Accessories,
pages 36 and 37). Follow instructions in-
cluded with the remote control.
Figure 58 - Thermostat Hand-Held Remote Control Unit Selections (GHRCTA Series Only)
Shows Temperature
Setting
Increases Room
Temperature in AUTO
Mode
Decreases Room
Temperature in AUTO
Mode
Turns Burners On or Off
and Allows You to
Choose the Auto Setting
The Log Heater will
Automatically Cycle
between Pilot and the
Heat Setting that has
been Selected
IMPORTANT:
This remote control
has been specially engineered to
take an air temperature sample ev-
ery minute in the auto mode. It will
not respond immediately to the
temperature setting being turned
up or down.
IMPORTANT:
The hand-held re-
mote control unit must be near the
heater. Do not keep the hand-held
remote control unit too close to the
heater. The thermostat on the
hand-held remote control unit will
heat up too quickly and turn the
heater off.
3. To turn the burner off, press the
AUTO/ON/OFF button until OFF
lights. The pilot will remain lit.
IMPORTANT:
To turn the pilot off,
manually turn the control knob on the
heater to the OFF position.
OPERATING
OPTIONAL GWMS2
WALL MOUNTED
SWITCH
Make sure the heater switch is on AUTO.
This wall switch works just like the con-
ventional light switch. Flip the switch up
for on and down for off.
Note:
Make sure that this switch is not in
a position to be mistaken for a light switch.
This may result in the heater being inad-
vertently turned on without the proper
precautions being taken. See installation
instructions on page 22 of this manual.