Desa CVDA18R Water Heater User Manual


 
901273-01D
12
For more information, visit www.desatech.com
For more information, visit www.desatech.com
T
INSPECTING BURNERS
Pilot Assembly
Burner Flame Pattern
CLEANING AND MAINTENANCE
REPLACEMENT PARTS
Pilot
Adjustment
Screw
Thermocouple
INSPECTING BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper flame height.
Alterations may have occurred during shipping and handling. The
pilot is located on the back right hand side of the burner.
The thermocouple should be fully enveloped in the flame. The flame
should not be lifting off of the thermocouple element.
If your pilot assembly does not meet these requirements:
Turn the adjustment screw marked pilot clockwise to decrease
or counterclockwise to increase the flame to proper size (see
Figure 20). Do not remove the adjustment screw.
see Troubleshooting, pages 13 through 15
Figure 19 - Correct Pilot Flame Pattern
Figure 21 - Typical Flame Pattern
BURNER FLAME PATTERN
Burner flames will be steady; not lifting or floating. Flames should
go up through the middle of logset. Flames should not "spill" to the
edges of the pan or sides of the logset.
Figure 21 shows a typical flame pattern. If burner flame pattern differs
from that described:
turn appliance off (see To Turn Off Gas to Appliance, page 11)
see Troubleshooting, pages 13 through 15
REPLACEMENT PARTS
Note:
Use only original replacement parts. This will protect your
warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply
original replacement part(s), call DESA International’s Technical
Service Department at 1-866-672-6040. When calling DESA Inter-
national, have ready
your name and address
model and serial numbers of your log set
how log set was malfunctioning
type of gas used (propane or natural gas)
purchase date
Usually, we will ask you to return the defective part to the factory.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this product. If they can’t supply original
replacement part(s), call DESA International at 1-866-672-6040.
When calling DESA International, have ready
model number of your log set
the replacement part number
Figure 20 - Locating Pilot Adjustment Screw
Pilot
CLEANING AND
MAINTENANCE
Keep the area around the log set clean and clear of debris.
Occasionally, you may use a soft bristle brush to clean logs.
Periodically inspect the air mixer and burner tube for foreign
matter blocking the air inlet and flame holes.
Once every year a qualified agency or certified chimney sweep
should examine and clean the venting system of the fireplace.