Desa CLD3924NTA Electric Heater User Manual


 
107068-01D
For more information, visit www.desatech.com
For more information, visit www.desatech.com
10
INSTALLATION
Installing Damper Clamp Accessory For Vented Operation
Installing Heater Base Assembly
INSTALLATION
Continued
Area of Various Standard
Round Flues
Diameter (ins.) Area (sq. ins.)
5" 20 sq. inches
6" 29 sq. inches
7" 39 sq. inches
8" 51 sq. inches
INSTALLING DAMPER CLAMP ACCESSORY
FOR VENTED OPERATION
Note:
When used as a vented heater, appliance must be installed
only in a solid-fuel burning fireplace with a working flue and
constructed of noncombustible material.
If your heater is a manually-controlled model, you may use this
heater as a vented product. There are three reasons for operating
your heater in the vented mode.
1. The fireplace does not meet the clearance to combustibles re-
quirements for vent-free operation.
2. State or local codes do not permit vent-free operation.
3. You prefer vented operation.
If reasons number 1 or 2 above apply to you, you must permanently
open chimney flue damper. You must install the damper clamp
accessory (to order, see Accessories, page 32). This will insure vented
operation (see Figure 10). The damper clamp will keep damper open.
Installation instructions are included with clamp accessory.
See chart below for minimum permanent flue opening you must
provide. Attach damper clamp so the minimum permanent flue
opening will be maintained at all times.
Chimney Minimum Permanent
Height (ft.) Flue Opening (sq. ins.)
6' to 15' 39 sq. inches
15' to 30' 29 sq. inches
Figure 10 - Attaching Damper Clamp
INSTALLING HEATER BASE ASSEMBLY
WARNING: If installing in a sunken fireplace, special
care is needed. You must raise the fireplace floor to
allow access to heater control panel. This will insure
adequate air flow and guard against sooting and con-
trols being damaged. Raise fireplace floor with non-
combustible material. Make sure material is secure.
CAUTION: Do not pick up heater base assembly
by the burner. This could damage heater. Only handle
base assembly by grates.
WARNING: You must secure this heater to fire-
place floor. If not, heater will move when you adjust
controls. Moving heater may cause a gas leak.
IMPORTANT:
Make sure the heater burners are level. If heater is
not level, heater will not work properly. For thermostat models,
avoid damage to thermostat bulb. Avoid nicks or sharp bends in
thermostat bulb wire. Keep thermostat bulb in mounting bracket
until ready to mount base to floor. See Optional Positioning Of
Thermostat Sensing Bulb, page 24.
Installation Items Needed
hardware package (provided with heater)
approved flexible gas hose (not provided) (if allowed by local codes)
sealant (resistant to propane/LP gas, not provided)
electric drill with 3/16" drill bit
flathead screwdriver
1. Apply pipe joint sealant lightly to male threads of the fitting to
be threaded into gas regulator. Connect approved flexible gas
hose to gas regulator of heater (see Figure 11, page 11).
IMPORTANT:
Hold gas regulator with wrench when connect-
ing flexible gas hose.
2. Locate masonry screws in hardware package.
3. Position heater base assembly in fireplace.
4. Place logs in their proper position on heater base (see Install-
ing Logs, pages 13 through 15).
5. Center heater base and logs front-to-front and side-to-side in
fireplace.
6. Carefully remove logs without moving heater base.
CAUTION: Do not remove the data plates attached
to the heater base assembly. The data plates contain
important warranty and safety information.
Manufactured Fireplace
Masonry Fireplace
Damper
Damper Clamp
Damper
Damper