www.desatech.com
113101-01C 17
Figure 20 - Installing Crossover Logs
Crossover
Log (#3)
Pegs
INSTALLATION
Continued
INSTALLING LOGS, MODELS
CLD3018PTA, CLD3018NTA,
CLD3924PTB AND CLD3924NTB
WARNING: Failure to position
the parts in accordance with these
diagrams or failure to use only
parts specifically approved with
this heater may result in property
damage or personal injury.
CAUTION: After installa-
tion and periodically thereafter,
check to ensure that no flame
comes in contact with any log.
With the heater set to High, check
to see if flames contact any log. If
so, reposition logs according to
the log installation instructions
in this manual. Flames contact-
ing logs will create soot.
Each log is marked with a number. These numbers
will help you identify the log when installing. It
is very important to install these logs exactly as
instructed. Do not modify logs. Only use logs
supplied with heater.
1. Place the base of the middle log (#1) in the
U-shaped slots of the grate base. The cutout
on the right of the middle log should fit over
the burner (see Figure 21). Make sure the front
of the middle log is resting on the tabs of the
grate base and the cutout area is centered over
the burner “U” bend.
2. Locate pegs on the bottom of back log (#2).
Slide these pegs into the holes in the grate base
behind the burner (see Figure 22).
3. Slide log (#3) over left end of log (#4). Place
these logs on the grate fingers. Make sure the
notches of the front log line up with the grate
fingers (see Figure 23, page 18).
Figure 21 - Installing Middle Log (#1)
Middle Log (#1)
Tab
Burner
“U” Bend
U-Shaped Slot
Figure 22 - Installing Back Log (#2)
Hole in Grate
Base
Back Log
(#2)
Peg
Burner
Crossover
Log (#4)
Pegs