Desa CGR35NA Electric Heater User Manual


 
35
100792
TECHNICAL
SERVICE
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-
5190.
35,000 BTU/Hr 50,000 BTU/Hr 65,000 BTU/Hr
Model Model Model
BTU 35,000 50,000 65,000
Type Gas Natural Only Natural Only Natural Only
Ignition Piezo Piezo Piezo
Pressure Regulator Setting 3.5" W.C. 3.5" W.C. 3.5" W.C.
Inlet Gas Pressure
Maximum 7" W.C. 7" W.C. 7" W.C.
Minimum 5" W.C. 5" W.C. 5" W.C.
Dimensions, Inches
Heater (H x W x D) 25 x 27
1
/4 x 16 28 x 32
1
/2 x 16 31 x 37
3
/4 x 16
Shipping Weight (pounds) 97 133**/120 158**/145
Flue Vent Size 4" dia. 4" dia. 5" dia.
Orifice Size 34 drill, ø .111 29 drill, ø .136 3.8 mm, ø .1496
** When equipped with blower
SPECIFICATIONS
When gas pressure is too low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
When gas quality is bad
• pilot will not stay lit
• burner will produce yellow flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local natural gas supplier.
SERVICE
HINTS
Note:
These heaters are certified for elevations of 0-4500 feet above sea level. For
elevations above 2000 feet, de-rate heater 4% for each 1000 feet above sea level.