Desa CGN18B Electric Heater User Manual


 
23
100096
TROUBLE-
SHOOTING
Continued
OBSERVED
PROBLEM
Burner does not light
after ODS/pilot is lit
(continued from page
22)
Delayed ignition of
burner
Burner backfiring
during combustion
Yellow flame during
burner combustion
Slight smoke or odor
during initial opera-
tion
Heater produces a
whistling noise when
burner is lit
POSSIBLE
CAUSE
2. Burner orifice diameter
is too small
3. Inlet gas pressure is
too low
1. Manifold pressure is
too low
2. Burner orifice is
clogged
1. Burner orifice is
clogged or damaged
2. Burner damaged
3. Gas regulator defective
1. Not enough air
2. Gas regulator defective
1. Residues from manu-
facturing processes
1. Turning control knob
to HIGH position
when burner is cold
2. Air in gas line
3. Air passageways on
heater blocked
4. Dirty or partially
clogged burner orifice
REMEDY
2. Replace burner orifice
3. Contact local natural gas
company
1. Contact local natural gas
company
2. Clean burner (see
Cleaning and Mainte-
nance, page 21) or
replace burner orifice
1. Clean burner (see
Cleaning and Mainte-
nance, page 21) or
replace burner orifice
2. Replace burner
3. Replace gas regulator
1. Check burner for dirt
and debris. If found,
clean burner (see
Cleaning and Mainte-
nance, page 21)
2. Replace gas regulator
1. Problem will stop after a
few hours of operation
1. Turn control knob to
LOW position and let
warm up for a minute
2. Operate burner until air
is removed from line.
Have gas line checked
by local natural gas
company
3. Observe minimum
installation clearances
(see Figure 4, page 10)
4. Clean burner (see
Cleaning and Mainte-
nance, page 21) or
replace burner orifice
Continued