Desa CGN10TA Electric Heater User Manual


 
12
104267
VENT-FREE NATURAL GAS HEATER
CGN10TA and CGN10TLA
CLEANING AND
MAINTENANCE
CABINET
Air Passageways
Use a vacuum cleaner or pressurized air
to clean.
Exterior
Use a soft cloth dampened with a mild
soap and water mixture. Wipe the cabi-
net to remove dust.
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, pet hair, etc.
1/2 GLASS HEIGHT
BURNER FLAME PATTERN
Figure 19 shows a correct burner flame
pattern. Figure 20 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame. It
also shows the flame higher than 1/2 the
glass panel height.
WARNING: If yellow tipping
occurs, your heater could pro-
duce increased levels of carbon
monoxide. If burner flame pattern
shows yellow tipping, follow in-
structions at bottom of this page.
NOTICE: Do not mistake orange
flames with yellow tipping. Dust
or other fine particles enter the
heater and burn causing brief
patches of orange flame.
Figure 19 - Correct Burner Flame Pattern
Figure 20 - Incorrect Burner Flame Pattern
Yellow
Tipping
1/2 GLASS HEIGHT
INSPECTING
BURNER
Check pilot flame pattern and burner flame
pattern often.
PILOT FLAME PATTERN
Figure 17 shows a correct pilot flame pat-
tern. Figure 18 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the heater will shut
down.
If pilot flame pattern is incorrect, as shown
in Figure 18
turn heater off (see To Turn Off Gas to
Appliance, page 11)
see Troubleshooting, pages 13 through 15
Figure 17 - Correct Pilot Flame Pattern
Figure 18 - Incorrect Pilot Flame Pattern
GRH/OV 009GOOD PILOT
Thermocouple
Pilot Burner
Thermocouple
GRH/OV 008BAD PILOT/LP
Pilot Burner
If burner flame pattern is incorrect, as shown
in Figure 20
turn heater off (see To Turn Off Gas to
Appliance, page 11)
see Troubleshooting, pages 13 through 15
ODS/PILOT AND BURNER
ORIFICE
Use a vacuum cleaner, pressurized air,
or small, soft bristled brush to clean.
CLEANING BURNER
PILOT AIR INLET HOLE
We recommend that you clean the unit every
2,500 hours of operation or every three months.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust
and dirt. To clean these parts we recommend
using compressed air no greater than 30 PSI.
Your local computer store, hardware store, or
home center may carry compressed air in a
can. You can use a vacuum cleaner in the
blow position. If using compressed air in a
can, please follow the directions on the can.
If you don't follow directions on the can, you
could damage the pilot assembly.
1. Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.
2. Inspect burner, pilot for dust and dirt.
3. Blow air through the ports/slots and
holes in the burner.
Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
the pilot assembly. There is a small pilot air
inlet hole about two inches from where the
pilot flame comes out of the pilot assembly
(see Figure 21). With the unit off, lightly
blow air through the air inlet hole. You may
blow through a drinking straw if compressed
air is not available.
Figure 21 - Pilot Inlet Air Hole
Pilot Assembly
Pilot Air Inlet Hole