Desa CGN10L Electric Heater User Manual


 
19
103546
1/2 GLASS HEIGHT
INCORRECT FLAME PATTERN
AT HIGH POSITION
NOTICE
Do not mistake orange flames with yellow tipping. Dust or other
fine particles enter the heater and burn causing brief patches of
orange flame.
BURNER FLAME PATTERN
Figure 19 shows a correct burner flame pattern. Figure 20 shows an incorrect
burner flame pattern. The incorrect burner flame pattern shows yellow tipping of
the flame. It also shows the flame higher than 1/2 the glass panel height.
INSPECTING
BURNER
Continued
WARNING ICON G001
WARNING
If yellow tipping occurs, your heater could produce increased
levels of carbon monoxide. If burner flame pattern shows yellow
tipping, follow instructions at bottom of this page.
If burner flame pattern is incorrect, as shown in Figure 20
• turn heater off (see To Turn Off Gas to Appliance, page 18)
• see Troubleshooting, pages 20 through 23
CORRECT FLAME PATTERN
AT HIGH POSITION
1/2 GLASS HEIGHT
Yellow
Tipping
(Model CGN6 will be lower due to lower input rating)
Figure 20 - Incorrect Burner Flame Pattern
Figure 19 - Correct Burner Flame Pattern
(Model CGN10A)