Desa CGFP28N Indoor Fireplace User Manual


 
8
103413
UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE
CGFP28N and CGFP28NT
AUTO
OFF
ON
3
2
1
INSTALLATION
Continued
1. Remove fireplace screen (see Figure 7).
Figure 8 - Removing Log Base from
Fireplace
NOTICE: Shut-off gas supply and
disconnect heater from gas sup-
ply. Contact a qualified service
person to do this.
CAUTION: Do not pick up log
base assembly by burners. This
could damage burners. Only
handle base by grates.
Screws
Log Base
Flexible Gas Line
2. If logs are installed, carefully remove
the logs and set aside, noting the prop-
erly mounted location of each.
3. Remove screws that attach log base as-
sembly to fireplace (do not discard).
Carefully lift up log base assembly and
remove from fireplace, taking care to
pull flexible gas line through the ac-
cess holes (see Figure 8).
Figure 7 - Removing Fireplace Screen
WARNING: You must operate
this fireplace with the fireplace
screen in place. Make sure fire-
place screen is in place before
running fireplace.
Notches
Screen Mounting Screws
Figure 9 - Mounting Blower to Firebox
Figure 10 - Installing Power Cord,
Mounting Plate, and Selector switch
Figure 11 - Installing Switch and Cover
Assembly
Blower
#8 Screws
Lower Rear
Wall of Firebox
Exhaust
Port
#6 Screws
#10 Screw
Wire
Clips
Selector
Switch
Switch and Cover Assembly
4. Place the blower against lower rear wall
of firebox outer wrapper with the ex-
haust port directed upward. Align the
holes in top mounting tabs of blower
with holes in wall of wrapper (see Fig-
ure 9). Using two #8 screws provided,
mount blower and tighten screws firmly.
5. Route terminals end of power cord
through large hole near top of left floor
support bracket. Make sure to pass the
cord from the outside (left side) towards
the center of firebox (see Figure 10).
6. Using two #6 screws provided attach
power cord mounting plate to the out-
side face of left floor support bracket.
Drive screws from inside (right side)
of floor support bracket. Attach the
plate so that the power cord is directed
towards rear of firebox (see Figure 10).
Tighten screws firmly.
7. Remove the three screws (do not dis-
card) and cover plate from center of
firebox wrapper rear wall. Discard this
cover plate.
8. Mount the supplied thermostatic switch
and cover assembly into firebox wrap-
per wall. Do this by feeding terminal
ends of wire harness into the hole. Al-
low wires to fall to bottom of firebox
cavity (see Figure 11).
9. Using three screws from step 7, attach
switch and cover assembly to firebox
wrapper rear wall. Tighten screws
firmly (see Figure 11).
10. Mount selector switch to front flange
of left floor support bracket. Align
graphics on switch upright and push
firmly to snap switch into rectangular
hole. Push the selector switch to the off
(middle) position (see Figure 10).
WARNING: Failure to connect
all wires properly as indicated
may cause electrical short circuit
or personal injury. A qualified
electrician should check that all
connections are made properly.
INSTALLING GA3650T
BLOWER ACCESSORY
(For CGFP28P Model Only)