Desa CGCFTP, CGCFTN Indoor Fireplace User Manual


 
www.desatech.com
111044-01J24
TROUbLESHOOTING
Continued

Yellow flame during burner
combustion
Slight smoke or odor during initial
operation
Fireplace produces a whistling
noise when burner is lit
White powder residue forming
within burner box or on adjacent
walls or furniture
Fireplace produces a clicking/
ticking noise just after burner is
lit or shut off

1. Not enough air
2. Gas regulator defective
1. Residues from manufacturing
processes
1. Turning control knob to HI
position when burner is cold
2. Air in gas line
3. Air passageways on replace
blocked
4. Dirty or partially clogged
burner orice
1. When heated, vapors from
furniture polish, wax, carpet
cleaners, etc. may turn into
white powder residue
1. Metal expanding while heating
or contracting while cooling
REMEDY
1. Check burner for dirt and
debris. If found, clean burner
(see Cleaning and Mainte-
nance, page 20)
2. Replace gas regulator
1. Problem will stop after a few
hours of operation
1. Turn control knob to LO
position and let warm up for
a minute
2. Operate burner until air is
removed from line. Have gas
line checked by local propane/
LP gas company
3. Observe minimum installation
clearances (see Figures 6 and
7, page 9)
4. Clean burner (see Cleaning
and Maintenance, page 20)
or replace burner orice
1. Turn heater off when using
furniture polish, wax, carpet
cleaners or similar products
1.
This is normal with most re-
places. If noise is excessive,
contact qualied service person