Desa CFS18NR Electric Heater User Manual


 
22
103449
UNVENTED NATURAL GAS LOG HEATER
DESA INTERNATIONAL
REPLACEMENT
PARTS
Note:
Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Techni-
cal Service Department at 1-800-323-5190.
When calling DESA International, have ready
your name
your address
model number of your heater
how heater was malfunctioning
type of gas used (propane or natural gas)
purchase date
Usually, we will ask you to return the defec-
tive part to the factory.
PARTS NOT UNDER
WARRANTY
Contact authorized dealers of this product. If
they can’t supply original replacement part(s),
call DESA International’s Parts Department
at 1-800-972-7879 for referral information.
When calling DESA International, have ready
model number of your heater
the replacement part number
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact DESA International’s Technical
Service Department at 1-800-DESA LOG
(1-800-337-2564).
You can also visit DESA International’s
technical services web site at
www.desatech.com.
SPECIFICATIONS
18" Variable 24" Variable 30" Variable
Btu (Variable) 16,000/26,000 20,000/33,000 21,500/36,000
Type Gas Natural Gas Only Natural Gas Only Natural Gas
Only
Ignition Piezo Piezo Piezo
Manifold Pressure 3.4" W.C. 3.4" W.C. 3.4" W.C.
Inlet Gas
Pressure (in. of water)
Maximum 10.5" 10.5" 10.5"
Minimum* 5" 5" 5"
Shipping Weight 32 lbs. 34 lbs. 36 lbs.
* For purpose of input adjustment
WIRING DIAGRAM
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burners will have delayed ignition
heater will not produce specified heat
When Gas Quality Is Bad
pilot will not stay lit
burners will produce flames and soot
heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
natural gas supplier.
Receiver
Black
On
Off
Remote
Red
Red
White
Thermopile
Gas Control
TPTH TH
TPTH
TP