www.desatech.com
111347-01E
26
Capillary
Thermostat
Sensing Bulb
Do Not Crimp
Capillary
Adhesive-
backed
Mounting Clip
Figure 37 - Positioning the Thermostat
Sensing Bulb in the Vertical Position
with the Capillary at the Bottom
OPTIONAL POSITIONING
OF THERMOSTAT
SENSING BULB
Continued
SPECIFICATIONS
Echo Valley Oak Log
Variable Manually-Controlled
Btu (Variable) 16,000/31,500
Type Gas Propane/LP - Natural
Ignition Piezo
Manifold Pressure 8.0" W.C. - 3.5" W.C.
Inlet Gas Pressure (in. of water)
Maximum 14" - 10.5"
Minimum* 11" - 5"
Shipping Weight 38 lbs.
* For purpose of input adjustment
Meadowbrook Oak Log
Thermostatically-Controlled
Btu (Variable) 26,000/39,000
Type Gas Propane/LP - Natural
Ignition Piezo
Manifold Pressure 8.0" W.C. - 3.5" W.C.
Inlet Gas Pressure (in. of water)
Maximum 14" - 10.5"
Minimum* 11" - 5"
Shipping Weight 28 lbs.
* For purpose of input adjustment
4. The mounting clip must be a minimum of 3" from
bottom of fireplace to prevent crimping of capil
-
lary. Once you have decided on a location, clean
the area thoroughly. Remove the paper backing
from the adhesive on back of mounting clip. Press
the clip into the new location so that the thermostat
sensing bulb will be positioned vertically with the
capillary at the bottom (see Figure 37). Slide the
thermostat sensing bulb into the clip.
IMPORTANT: Do not crimp capillary.