Desa CD42M-A2 Indoor Fireplace User Manual


 
www.desatech.com
111916-01F 9
INSTALLATION
Continued
ELECTRICAL HOOKUP AND
REMOTE RECEIVER DIAGRAM
An outlet box with two receptacles (see Figure 9) has
been supplied for your convenience and is located
inside on the lower right side of the fireplace.
The remote control receiver is factory wired and
connected to the convertible gas valve as shown
in Figure 10.
Figure 9 - Duplex Outlet
Three-prong Plug
Figure 10 - Remote Control Receiver
Outlet Box
Remote
Control
Receiver
Convertible
Gas Valve
GAS SUPPLY TESTING
NOTICE: This section is in-
tended as a guide for qualified
technicians installing gas to the
appliance.
WARNING: Do not connect
appliance before pressure test-
ing gas piping. Damage to gas
valve may result and an unsafe
condition may be created.
The appliance and its individual shutoff valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas sup-
ply piping system by closing its individual shutoff
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 psig (3.5 kPa).
The gas control valve is secured underneath the
firebox. Two 1/8" ports are provided on the gas
control valve for pressure test gauge connections
(see Figure 11).
Figure 11 - Gas Control Valve
ON/OFF
Knob
Pilot Adjustment
Inlet
Pressure
Outlet
Pressure
Flame
Adjustment Knob
Pilot Gas Line
Do Not Kink
To Pilot
Burner
To Main
Burner
GAS LINE HOOK-UP
WARNING: Gas line hook-
up should be done by your gas
supplier or a qualified service
person.
WARNING: Before you pro-
ceed, make sure your gas supply
is OFF.
An equipment shutoff valve has been included in
the fireplace's gas supply system. However, con-
sider installing an extra shutoff valve outside the
applianceʼs enclosure (check local codes), where
it can be accessed more conveniently with a key
through a wall as shown in Figure 12.
Figure 12- Typical Exterior Wall Gas
Shutoff Installation
Key
Extension
Shutoff
Valve