Desa BLP35ES Electric Heater User Manual


 
13
IF GAS LEAK
OCCURS
!
WARNING
If you detect a gas leak, turn off propane supply at once.
Ventilate the area. Wait until five minutes after propane odor is
not present. Follow steps below to check for gas leak.
!
WARNING
Never use an open flame to check for a leak. Apply a mixture
of liquid soap and water to all joints. Bubbles forming show a
leak. Correct all leaks at once.
1. After turning off propane supply and ventilating area, unplug heater power
cord.
2. Turn propane supply on.
3. Apply a mixture of liquid soap and water to hose and connections between
propane tank(s) and heater inlet. Bubbles forming show a leak.
4. Turn propane supply off and ventilate the area. Repair leak.
5. Wait until five minutes after propane odor is not present before restarting
heater.
6. If you cannot repair leak, contact you local service center.
SPECIFICATIONS
Model BLP35ES
Electrical Input 220/240 volt, 50 hertz, 55 watts IP20
Maximum Input, net 10.3 KW at 27 millibar
Regulator Output 27 millibar
Burner Rate 10.3 KW, 796 g/hr
Supply Pressure (min.) 2 bar
Ventilation 260 cm
2
Room Size 103 cubic meters
Air Delivery Class Type A
Temperature Range for Heater Operation -29° C to 29° C*
* When running heater in temperatures above 29° C, high internal temperatures
may cause thermal limit device to shut down heater.