Desa B200 Electric Heater User Manual


 
6
102569
PORTABLE FORCED AIR HEATER
200,000 Btu/Hr
Item How Often How To
Fuel tank Flush every 150-200 hours See Storing, Transporting,
of operation or as needed or Shipping
Air output and Replace every 500 hours of See Air Output, Air Intake,
lint filters operation or once a year and Lint Filters, page 8
Air intake filter Wash and dry with soap and See Air Output, Air Intake,
water every 500 hours of and Lint Filters, page 8
operation or replace as needed
Fuel filter Clean twice a heating season See Fuel Filter, page 9
or replace as needed
Spark plug Clean and regap every 600 See Spark Plug, page 10
hours operation or replace
as needed
Fan blades Clean each season or as needed See Fan, page 8
Motor Not required/permanently lubricated
WARNING: Never service
heater while it is plugged in, op-
erating, or hot. Severe burns and
electrical shock can occur.
STORING,
TRANSPORTING,
OR SHIPPING
Note:
If shipping, transport companies re-
quire fuel tanks to be empty.
1. Drain fuel tank.
Note:
This model has a drain plug on
underside of fuel tank. Remove drain
plug to drain all fuel. Be sure all fuel is
removed.
2. Replace drain plug.
3. If any debris is noted in old fuel, add 1
or 2 quarts of clean kerosene to tank,
stir, and drain again. This will prevent
excess debris from clogging filters dur-
ing future use.
4. Replace fuel cap and drain plug. Prop-
erly dispose of old and dirty fuel. Check
with local automotive service stations
that recycle oil.
5. If storing, store heater in dry place.
Make sure storage place is free of dust
and corrosive fumes.
IMPORTANT:
Do not store kerosene over
summer months for use during next heating
season. Using old fuel could damage heater.
PREVENTATIVE
MAINTENANCE
SCHEDULE