Desa 000 55 Fan User Manual


 
8
099176
OPERATION
Continued
Item How Often How To
Fuel tank Flush every 150-200 hours See Storage above.
of operation or as needed.
Air output and Replace every 500 hours of See Air Output, Air Intake,
lint filters operation or once a year. and Lint Filters, page 10.
Air intake Wash and dry with soap and See Air Output, Air Intake,
filter water every 500 hours of op- and Lint Filters, page 10.
eration or replace as needed.
Fuel filter Clean twice a heating season See Fuel Filter, page 11.
or replace as needed.
Spark plug Clean and regap every 600 See Spark Plug, pages 11
hours operation or replace and 12.
as needed.
Fan blades Clean each season or as needed. See Fan, page 10.
Motor Not required/permanently lubricated
WARNING
!
PREVENTATIVE
MAINTENANCE
SCHEDULE
Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.
STORAGE
1. Drain fuel tank.
Note:
Some models have drain plug on underside of fuel tank. If so, remove
drain plug to drain all fuel. If heater does not have drain plug, drain fuel
through fuel cap opening. Be sure all fuel is removed.
2. Replace drain plug if used.
3. Add one gallon of clean kerosene to fuel tank.
4. Attach fuel cap.
5. Move heater forwards and backwards to stir fuel.
6. Remove fuel cap or drain plug and drain fuel tank. Be sure all fuel is removed.
7. Replace fuel cap or drain plug. Properly dispose of old and dirty fuel.
8. Store heater in dry place. Make sure storage place is free of dust and corrosive
fumes.
IMPORTANT:
Do not store kerosene over summer months for use during next
heating season. Using old fuel could damage heater.
To Stop Heater
1. Unplug extension cord from outlet.
To Restart Heater
1. Wait two minutes after stopping heater.
2. Repeat steps under To Start Heater, page 7.