Denso OFFICE PRO 24 Air Conditioner User Manual


 
20
TECHNICAL SPECIFICATIONS
ITEM/FEATURES Office Pro 12 Office Pro 24
Rating Conditions
dry bulb 95º F (35º C) 95º F (35º C)
wet bulb 83º F (28.2º C) 83º F (28.2º C)
humidity (60%) (60%)
Specifications
power frequency 60Hz 60Hz
line voltage single phase 115 V single phase 208/230V
power consumption 1.23 Kw 2.7 Kw
current consumption 11.3 Amps 13.1/11.8 Amps
power factor 95% 99%
starting current 32A 32.9A
power wiring 14 (3-core) AWG 12 (3-core) AWG
Cooling Unit
cooling capability 2,950 Kcal/hr 6,000 Kcal/hr
11,700 BTU/hr 24,000 BTU/hr
cooling system direct expansion direct expansion
Blower
type of fan centrifugal fan centrifugal fan
air volume: Evaporator (High speed) 441 ft
3
/min (745 m
3
/h) 632 ft
3
/min (1068 m
3
/h)
Condenser (High speed) 823 ft
3
/min (1391 m
3
/h) 867 ft
3
/min (1465 m
3
/h)
motor output (High) 0.14 Kw 0.48 Kw
(Low) 0.08 Kw 0.41 Kw
Compressor
type rotary rotary
output 0.8 Kw 1.4 Kw
refrigerant type R-22 R-22
refrigerant capacity 0.95 lbs (0.43 kg) 2.17 lbs (0.96 kg)
Safety Devices
compressor overload protector included included
fan motor protector included included
anti-freezing thermistor included included
full drain tank switch included included
automatic restart (power interruption)
included included
compressor time delay program included included
Dimensions & Weight
W x D x H (in) 21.2" x 27.4" x 44" 21.2" x 27.4" x 47.25"
W x D x H (mm) 538 x 696 x 1118 538 x 696 x 1200
weight (lbs/kg) 165 / 75 210 / 95
Operating Conditions
inlet air (relative humidity) 95º F (35º C), 60% 95º F (35º C), 60%
65º F (18.3º C), 50% 65º F (18.3º C), 50%
Control Device
temperature control included included
programmable timer included included
two speed fan included included